Filter Results By:
Products
Applications
Manufacturers
- CAMI Research Inc.
product
4-Wire Resistance Measurement | Continuity & HiPot Cable & Wire Harness Testers
An add-on option for the CableEye HVX high voltage cable tester series that permits expanded testing for contact and wire resistance as low as 1 mΩ. After checking for opens, shorts, miswires, and resistance limits, the 4-wire Kelvin measurement applies a user-selectable test current from 10 mA to 1 A to determine connection resistance within 1 mΩ. The resistance profile of a model cable may be stored and used as a basis of comparison during later testing to reveal cold solder joints, faulty crimps, recessed pins, pin contact contamination, improper wire gauge, and stress-extruded wire.This option may be purchased with any new HVX tester, or added as an upgrade to any of your existing HVX testers.
-
product
Current Transformer Analyzer
CT Analyzer
Current transformer testing in a multifunctional instrument performing excitation, ratio, polarity and winding resistance tests on current transformers as well as burden impedance measurement.
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
Winding Resistance Meter
TRM 104
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
product
Highly Inductive Resistance Meter
MR 8050
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
product
STDETransformer Demagnetizer
STDE
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
product
Current Transformer Tester
CTT
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
product
Transformer Winding Resistance Meters
RMO TT Series
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
product
Transformer DC Winding Resistance Tester
HTZZ-5A / 230
Wuhan Huatian Electric Power Automation Co., Ltd.
Applicable for transformer to submit the dc resistance testproject around group in pick up and overhaul project.
-
product
Mini Automatic Transformer Observation System
mini-ATOS
The mini-ATOS, is a professional multifunctional power transformer and substation diagnostic system. This compact and intelligent instrument can perform many routine and advanced tests such as Winding Resistance (WR), Dynamic Resistance Measurement (DRM), Turns Ratio (TR), Frequency Response of Stray Losses (FRSL), Magnetic Balance, and other diagnostic parameters. With the built-in fully automatic multiplexer, only a one-time connection is required for nearly all functions, which saves a considerable amount of time. The portable, rugged case is perfect for use anywhere onsite or in a laboratory. It is specially designed for fast and easy measurements with the well-known high precision and quality of all Raytech instruments.
-
product
Winding Resistance Tester
JYR20S/10S
DC winding resistance testing is regarded as another essential routine screening tool. It indicates problems such as loose, defective or incorrect connections, which cause enough transformer failures each year to be regarded as a failure category of its own.
-
product
Tap Changer Analyzers & Winding Ohmmeters
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
product
Winding Resistance Meter 50Amps, 3 Channels
WR50-13
Raytech Digital Winding Resistance meter WR50-13 is the enhanced version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
product
Transformer Demagnetization Tester
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
product
Micro-ohmmeters
MMR-650
Designed to measure very low resistances of both resistive and inductive types of objects, including amorphous core transformers. This product is made to be used in power plants, railways and maintenance companies, to measure welded and soldered connections, equipotential bondings, earthing conductors, contacts, bolted connections, windings of motors and power transformers and other resistive and inductive objects. MMR-650 can be also utilized on a production lines (eg. at the final production control stage). An innovative combination of a high-performance measuring device with a modern user interface and advanced data management system. Wireless data transmission, enhanced system of 2D codes and ability to print labels to identify test items, all contribute to bringing new quality of work and allow the user to perform a wide range of measurements.
-
product
Motor/Generator Test Equipment
Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment include:Winding resistance measurement of generators and electrical motorsResistance measurement of high-current bus bar jointsResistance measurement of cable splicesAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, a DV-Win software generates a test report a single click. Finally, a user can easily customize the report and save it in different formats, such as XLS and PDF.
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
product
Winding Resistance Meter
* Selectable four resistance ranges.* 4 1/2 digits LED display* High measurement Current (10A)* True four Technique elimanates lead resistance errors Systems* Fully protected against overloads* Proven design* Computer connectivity through RS 232
-
product
Transformer Winding Resistance Tester
KRI 9310
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
product
Micro-Ohmmeters
Micro-Ohmmeter is an affordable 7 range, 4-Wire Kelvin based product that is used to test electrical resistance on a wide variety of applications including winding resistance, contact resistance, and component testing. The 720A micro-ohmmeter has an autorange feature (available with NSN package) and is compatible with an RS232C interface (OP-232). Thanks to its wide-range capabilities, ease of use, and CE mark, this micro-ohmmeter is used commonly across the globe.
-
product
Automatic Three Phase Transformer Ratio Meter
ATRM PLUS
*Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.
-
product
Winding Resistance Meter 50Amps, 2 Channels Rack
WR50-12R
Raytech Digital Winding Resistance meter WR50-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
product
Transformer Winding Resistance Meters
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
product
Transformer Winding Resistance Meters
RMO TD Series
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
product
Micro OHM Meter
Cambridge Instruments & Engineering Co.
This Test set is capable to measure low resistance like switch contacts, breaker contacts, busbar slices, joints, fuses, low inductive windings etc.
-
product
Transformer DC Winding Resistance Tester
HTZZ-40A / 245
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement transformer around the group and large power inductor dc resistance ideal equipment.
-
product
Winding Resistance Tester
JYR-50C/40C/20C
1. With demagnetization function.2. Testing range reach to 20k3. Also apply to testing tranformer with high winding resistance.
-
product
Resistance Measuring Equipment
measure coil winding resistance of motors, transformers, etc, under energizing AC voltage. The direct reading is possible with 4-wire measurement method, and temperature of specimens is immediately calculated from measured resistance values and displayed. Ambient temperature is automatically taken in by connecting an option sensor Model DAC-PT-100.
-
product
Winding Resistance Tester with Demagnetisation Circuit
WRT-10D
The WRT-10D is a high performance winding resistance tester designed for power transformer and large motor applications. It is equipped with a bright LCD display, a rugged high quality cable set, a built-in printer, a full QWERTY keypad and a demagnetisation circuit.