Filter Results By:
Products
Applications
Manufacturers
VDE
Verband der Elektrotechnik
- TEAM SOLUTIONS, INC.
product
PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit
APCI-3501-4
4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V
-
product
Peak Voltage Measurement
In high voltage measurement technology, the peak value, or the effective value, of the voltage is determined in accordance with VDE 0432 or IECV 60060. The peak voltage measuring device from MPS Mess- & Prüfsysteme GmbH can measure these two values in connection with a high voltage divider (capacitive or resistive). In the event of flashovers in the high-voltage circuit, this is indicated in the SMG.
-
product
12.5 mm Test Sphere Probe
CX-12.5
Shenzhen Chuangxin Instruments Co., Ltd.
The rigid sphere (12.5 mm) from Autostrong is designed and manufactured to perform the test specified in many standards (IEC 60335, IEC 60065, IEC 60745, IEC 61029, IEC 60950) to prove the degree of protection for the first characteristic numerals 2 (IP2X) .Its is designed to meet the requirements of international safety regulatory agencies such as UL, DNV, IMQ, BVSQ, ITS, IRAM , CSA, VDE, DIN , INMETRO.
-
product
Earth Meter
EM-4055
The EM-4055 Earth Meter is a digital, microprocessor-controlled instrument that allows to measure the earth resistance and ground resistivity (using Wenner´s method), as well as to detect parasitic voltages present in the ground. This instrument is well suitable to measure earth systems in power substations, industries, distribution networks, etc., according to VDE 0413. It is also suitable for soil resistivity measurements, in order to optimize the earth systems project
-
product
Socket-Outlet Torque Balance
CX-L12
Shenzhen Chuangxin Instruments Co., Ltd.
For measuring and testing the torque strain exerted by appliances with plug pins on socket-outlets in accordance with IEC 60065/1998-07 § 15.4.1 Fig. 11, IEC 60335-1 / 1991-04 § 22.3, IEC 60884-1 / 1994-06 § 14.23.2, EN 60335-1/1994 + A11 /1995 § 22.3, EN 60950/1992 + Amendments up to 1997-03 § 4.3.18, VDE 0700 Part 1 /1995-10 § 22.3, VDE 0805/1997-11 § 4.3.18
-
product
Insulation Resistance Tester
M300RT
Performs DC insulation resistance test " detects up to 4000 megohms at 500 VDC " Tests in compliance with UL, VDE, IEC and MIL STD 202 test standards. IEEE-488 optional
-
product
IP code Testing
Educated Design & Development, Inc.
Complies with various IEC, EN, CE, VDE, UL & CSA requirementsUnit comes with NIST traceable / ISO 17025 accredited certificate of calibration.ED&D is ISO 17025 accredited by ACLASS, an ILAC Member. Measurement data and uncertainty data is available.Uses RTS-01 Rain Spray Head
-
product
Insulation Meters
Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.
-
product
Installation Testers
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
product
Resistance Measuring Device According to DIN EN 61557-4 (VDE 0413-4)
PeakTech Prüf- und Messtechnik GmbH
An extremely robust milliohm measuring device in a splash-proof hard case for professional field service use, e.g. for resistance measurement on motor coils, generators and transformers or for continuity testing on ring bus systems in industrial plants.
-
product
Wire And Cable
Chengdu Mengsheng Electronics Co., Ltd.
We provide a variety of wire and cable products, including insulated wires, power cords, stranded wires, solid wires, wiring harnesses and connectors. Our products are widely used in security, medical, communications, instrumentation, medical, home appliances, auto parts, military, aerospace and other industries. Our products strictly comply with the product certification standards of countries and regions such as UL in the United States, VDE in Germany, CE in the European Union, and BS in the United Kingdom.
-
product
Ground Continuity Test Instrument
MODEL M25
Performs ground continuity tests in full compliance with BSI, VDE and IEC. Measures AC resistance from Chassis of Device Under Test (DUT) to power-cord ground lead - 0 to 0.15 ohm
-
product
Power Line Purpose Tester
LX-221A+
Shenzhen Lian Xin Technology Co., Ltd.
·Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards .·Used to test single – ends ,double –ends ,three-ends power supply cords.·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,·Provide with RS 232 interfaces, can communicate with PC, easy to upgrade,·Provide personalized customization according to different requirements.
-
product
General Power Relays
Panasonic Industrial Devices Sales Company of America
2A and greater load rating in Polarized, Non-Polarized, High Capacity DC, General Purpose, and Safety configurations. UL, CSA, C-UL, TUV, VDE, and SEMKO certifications.
-
product
Partial Discharge Test System
TPP
The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).
-
product
5 kV AC Hipot Testers
Models M100BVS5 & M500BVS5
Now you can perform safe, rapid and efficient hipot testing, ground continuity testing, and total or real current monitoring in one simple operation. The ROD-L Electronics model M100BVS5 and model M500BVS5 hipot testers perform safe and accurate AC hipot and ground continuity testing in compliance with UL, IEC, CSA, VDE, FCC and other electrical equipment testing standards
-
product
BSV Systems
In the medical field, electrical devices are used on which people's lives or healing processes depend. The highest demands are therefore placed on the devices required in the operating room or intensive care unit. Gustav Klein BSV systems guarantee an uninterrupted and safe power supply in accordance with VDE 0100 and ÖVE/ÖNORM E 8007.
-
product
Bilogical Antenna
For rapid deployment along with the mobility of small package, these Bilogical Antenna Kits provides an inexpensive solution to broadband applications. Suitable for FCC, MIL-STD, VDE, TEMPEST, and immunity testing, each Bilogical antenna will provide reliable, repeatable measurements. The ability to sweep in one trace makes the Bilogical antenna a versatile performer.
-
product
Partial Discharge Measuring System
LDS-6
The Doble LDS-6 is a highly sophisticated digital measuring system for partial discharge detection and analysis. It is trusted as a valuable tool for factory and laboratory testing.The LDS-6 can be used to test a variety of high voltage apparatus. Use the LDS-6 to perform PD quality tests on motors, generators, transformers, MV and HV cable systems, switchgear and additional HV accessories.The LDS-6 complies with IEC 60270, VDE 0434 as well as various IEEE and other standards.
-
product
Phase Detector
Paula
BAUR Prüf- und Messtechnik GmbH
BAUR paula phase detector. The paula phase detector is used for clear phase identification in earthed and shorted medium and high-voltage cables. With the help of the measurement procedure tried and tested over many years, paula delivers precise phase allocation without scope for interpretation and corresponds to the highest safety standards for tasks on and close to electric equipment.* Clear phase determination possible in cable lengths up to 40 km* Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)* Suitable for all switchgear constructions due to compact design of the signal injectors* Ready for operation for up to 2 weeks (standby mode)
-
product
Valve Position Sensors
*Dual inductive sensor for pneumatic actuators and valves*Designed for simple fit to common actuators based on VDI / VDE 3845*Quick and easy installation of the AS-i dual sensor*Position feedback for rising stem valves with up to 80 mm stroke*Reliable permanent valve monitoring
-
product
Dipole Antennas
Provides reliable, repeatable measurements. Suitable of FCC, MIL-STD, VDE, Tempest and Immunity stesting.
-
product
IEC60335 Inclined Plane Test Table for Stability Test
CX-W600
Shenzhen Chuangxin Instruments Co., Ltd.
It's to determine the stability of electric appliances which are used on a table or on the floorin accordance with IEC 60065 / 1998-07 clause 19.1, IEC 60335-1 / 1991-04 clause 20.1, IEC 60601-1 /1988 clause 24.1, IEC 60950 / 1991 + Amendments, modified, clause 4.1.1,EN 60335-1 / 1994 and A11 / 1995 clause 20.1, EN 60950 / 1992 + Amendments up to 1997 clause 4.1.1,VDE 0700 Part 1 / 10.95 clause 20.1 and Part 3 / 3.96 clause 20.1, VDE 0730 Part 1 / 3.72 clause 20a,VDE 0805 / 11.97 clause 4.1.1Inclined Plane Device is used to test the stability of an apparatus that requires a surface in order to work.The device cosist of a surface and an angle adjusting device with 0- 15 °
-
product
[5kV AC] Hipot Tester, Rise/Fall-Time Control Function Equipped
TOS5200
TOS5200 is designed for AC Hipot Test with 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by ACpower line. Therefore, it is a perfect solution for electronic equipment or devices complied to IEC, EN, UL, VDE andJIS etc. requirement.As TOS5200 covers most of features of our upper class model for AC Hipot Test, it achieves thesuperb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also, as it equips the Interlockfunction together with other safety features, operator can carry out the test with higher current value in safe.
-
product
Ammeter According to DIN EN 61010-1 (VDE 0411-1)
PeakTech Prüf- und Messtechnik GmbH
Is a measuring device for AC and DC currents up to 1000 A using a current clamp for conductor diameters up to 48 mm. Current and voltage measurements are carried out as true RMS (true rms value) measurements, which means that the measured values are displayed correctly even with waveforms that deviate from a sine wave.
-
product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
product
Combination Measuring Devices According to DIN EN 61557-10 (VDE 0413-10) are permitted
PeakTech Prüf- und Messtechnik GmbH
This innovative combination measuring device for testing electrical installations according to official laws convinces with its technical performance data in the high-end area. All important safety tests such as FI, voltage, loop, low-resistance, earth resistance and insulation tests for e-checks and new installations can be carried out safely by the electrician via the large 3.5“ TFT color display. Of course, the device comes with an extensive range of accessories, such as all necessary test leads, adapters, rods and the required software CD for the PC. The device can be charged with a power adapter or via a car adapter. During the daily use, this high-quality device is protected against dust and all-round water jets by its protection class IP 65.
-
product
Rotary Field Direction Indicator According to DIN EN 61557-7 (VDE 0413-7)
PeakTech Prüf- und Messtechnik GmbH
Direction indicators are indispensable for use in the electrical assembly of three-phase motors. This offers two different functions for displaying the direction of rotation. I
-
product
Earth Resistance Tester
PeakTech Prüf- und Messtechnik GmbH
A Rugged sealed digital earth tester is built with all the protection you need for outdoor use. The instrument is suitable for the testing of single earth electrodes such as lightning conductors and other small earthing systems according to VDE 0413. The resistance of conductors such as continuity and conduit coupling joints can also be measured. Two-terminal operation measurement, which reduces the accuracy, can also be done by shorting P and C terminals. It has an advanced circuit design that permits the instrument to operate with the minimum influence from earth voltage and earth resistance of the auxiliary spikes.
-
product
Voltmeter According to DIN EN 61010-1 (VDE 0411-1)
PeakTech Prüf- und Messtechnik GmbH
An innovative graphic multimeter with a 50,000-digit color TFT display for precise measurements with a high DC basic accuracy of 0.05%. The internal data logger enables the recording of measured values, which can be recorded over a period of several hours and the transfer to a Windows PC at a later time is ensured. Internally stored measured value recordings can also be accessed and graphically displayed on the multimeter itself or on the PC. Via Bluetooth, the measured values can also be displayed live via app for Android and iOS devices, recorded in a table and e.g. send by email for further processing. This multimeter has a variety of measurement functions for direct and alternating voltage measurements (incl.ACV + DCV), direct and alternating current measurements, resistance, capacitance, frequency or temperature, whereby alternating voltage and alternating current are recorded as True RMS values. Due to the extensive measurement functions and the intuitive operation, this device is ideally suited for every electronics engineer, technician and engineer who attach great importance to a precise, indestructible and technically powerful multimeter.