Filter Results By:
Products
Applications
Manufacturers
- Virginia Panel Corporation
product
ITA, G10, 10 Module, 0.5" Standard thickness
410104123
ITA, G10, 10 Module, 0.5" Standard ThicknessUses VPC 90 Series Modules.
-
product
Automatic Meter Reading Unit
Signals & Systems India Private Limited
SANDS make of AMR Modem SAM-1101 is a smart electricity meter reading device that can be connected to any make of electronic energy meter by means of optical/ RS232 port, which is compliant to DLMS – IEC 62056-21 standard. The electricity meters measuring energy consumption can be located in either consumer premises or in distribution transformers. The modem draws its power from the meter terminal block and connects to the communication port of the meter. Thus this add-on energy meter reading system is non-intrusive and can be retrofitted easily to any meter. The Electricity Meter Reading device uses GSM/GPRS communication technology and has built-in intelligence to talk to the DLMS meter. AMR system is compatible with 4G network to push the power consumption-billing data, load survey data, and event data to a cloud-based server, with fallback options to 3G & 2G.
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
Partial Discharge Monitor
doblePRIME PD-Guard
The doblePRIME PD-Guard continuously monitors partial discharge (PD) in equipment such as transformers, rotating machines, cables and switchgear.The doblePRIME PD-Guard provides local alarms and will communicate data and notifications across standard interface channels and through to networked supervisory systems. It analyzes RF emissions in the HF, VHF and lower UHF ranges.
-
product
904 Benchtop Six Phase 30A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard six phase voltage and six phase current output. It can test not only traditional relays andprotection devices, but also modern micro-computer protection devices, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. can be connected to laptop (optional) to run.Laptops and industrial computers use the same set of software, so there is no need to relearn the operation method.
-
product
Embedded Synchro - Resolver -
LVDT I/O Cards
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
product
Standard Voltage Transformer
HJ / 635
Wuhan Huatian Electric Power Automation Co., Ltd.
It is mainly designed for the voltage transformer calibration standard of basic power supply and production department.
-
product
Detection of PtG and PtP Faults on Multi and Single Core Cables
CableTroll 2350
CableTroll 2350 is an indicator for detection of PtG and PtP faults on multi and single core cables. The unit uses standard type current transformers. (40:1, 60:1 or 3x500:1)
-
product
STDETransformer Demagnetizer
STDE
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
product
RF Transformers
Pulse continues to lead the way with a broad range of components that enable twisted-pair copper high-speed services to homes and businesses. Pulse components are also used in cable modems and the consumer electronics that provide home networking services. Our high-performance transformers support home phone line and power line networks. These transformers are designed to exceed ANSI and ETSI standards, and have excellent THD performance and small footprints.
-
product
Current Transformer Tester
CTT
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
product
Transformer Test Panel/ Setup
This is a common test panel for distribution/ power transformers of different specifications. The user can perform most of the factory tests, as per the relevant IS standard for the transformers. The panel consists of power analyser, meters for high voltage test, meters for induced voltage test etc, control for all the tests, protection and interlock circuits so that a single panel can be used to conduct a number of tests using only one dimmerstat and the associated devices
-
product
Ratio Standards
Ratio Standards by Tegam including ratio transformers, synchro-resolver bridge, synchro-resolver standard
-
product
Current Transformers
Contrel Elettronica s.r.l. Company
We can supply current transformers (measure transformers, protection transformers and double ratio transformers, with analog output) with the following accuracy classes: 0.1, 0.2s, 0.5s; 1; 3. A wide range of combinations is available in our standard range with specific versions available upon request (other ratios, specific frequency, class or load). They are equipped with sealable terminal covers as standard.
-
product
Induced Over Voltage Test Set
We are highly experienced in manufacturing and exporting Induced Over Voltage/DFDV Test Set. It is widely used in electrical and power sector to test different types of transformers. Our range includes different models of testing set to meet clients' diverse requirements. Manufactured in accordance with industry standards, this Induced Over Voltage/DFDV Test Set is offered to clients at competitive price.
-
product
Environmental Test Probe, Temperature
72-8364
Type K Surface Temperature Probe Surface probe is ideal for flat stationary surfaces such as molds, heating elements, integrated circuits, transistors and transformers. Very low sensor element mass enables fast response measurement time. Type K thermocouple temperature probes are commonly used with all types of industrial temperature controls and measurement equipment, and are compatible with Tenma handheld thermometers and digital multimeters that include temperature function. All are terminated with standard Type K plugs. See the complete line of Tenma Thermocouple Probes and Accessories
-
product
Isolated LVDS
Isolated LVDS (low voltage differential signaling) devices couple differential signals applied to the LVDS receiver inputs across the isolation barrier to the outputs on the other side and re-transmits the bit stream or clock as LVDS. Analog Devices' drop-in LVDS isolators offer designers robust, high speed differential signaling for point-to-point and multidrop applications. Extending iCoupler® chip scale transformer technology for ultrahigh speed data encoding, these LVDS isolators support a a data rate of up to 2.5 Gigabits per channel for a total bandwidth of 10 Gbps. In contrast to expensive fiber implementations, deserialized links over standard digital isolators or optocouplers, and design-intensive bespoke solutions using transformers or high voltage capacitors, ADI Gigabit Digital LVDS isolators offer the only integrated comprehensive, high performance isolation at 10 Gbps. High performance galvanic isolation for applications include analog front-end (AFE), processor to processor serial communication, or video and imaging data (such as HDMI isolators) as well as isolation between boards, or at a cable interface for LVDS or CML signal chains.
-
product
Autotransformer
T-1007
The Titan Series T-1007 Auto-transformer is used to conveniently scale the standard OV to 130V / 260V full scale Titan AC Power Source/Frequency Converter output to either X .5 stepdown (OV to 65V) or X2 stepup (OV to 520V). It has a 1.2 KVA power rating with excellent bandwidth and voltage regulation.The unit is of toroidal design, making it approximately half the size and weight of a comparable stacked laminate transformer. It is center filled with epoxy for isolation and durability, and features simple 1/4" bolt center mounting.
-
product
ANSI Metering Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Computer Control 6-Phase Relay Protection Tester
GDJB-PC6
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
1.This tester with standard 6 phase voltage, 6 phase current output,2.Voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.3.Digital Signal Processor Microcomputer.4.Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.
-
product
ANSI Standard Burden Sets
Voltage and Current
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
product
Lab Moisture Analyzer
PC-Based laboratory/production Moisture Analyzer connects through the RS-232 Serial Port. For nuts, granules, powders, pellets, chips or flakes. Complete with:– MCPC-RS Test Chamber– Windows PC-Based Software– Two Sample Cups– Dial Thermometer– Standard Block– RS-232 Cable (10 Feet)– USB to RS232 Adapter– Operating Instructions Manual– 115VAC/60HZ Wall Transformer
-
product
SF6 Decomposition Products Detector
JH4000A-4
Xiamen Jiahua Electrical Technology Co.,Ltd
JH4000A-4 SF6 Electrical Equipment Decomposition Products Detector is a high precision, intelligent and portable device, able to make judgment rapidly and correctly based on the content of main decomposition products of insulation materials inside the SF6 electrical equipment like SF6 circuit breaker, instrument transformer, GIS and transformer. It detects SO2+SOF2, H2S, CO and HF. It is reliable, accurate and stable. Inspected by authorities such as the National Institute of Metrology, the device, having excellent performance, complies with relevant international and national standards. It is a product recommended for use by the State Power Grid Company. Decomposition products detection provides reliable evidence for the internal fault diagnosis and it is an effective measure for preventive and corrective maintenance.
-
product
ACP Portable Electrical Current Transformer Test,CT/PT Analyzer
Chongqing Assen Power Equipment Co., Ltd
ACP portable Current transformer analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
-
product
Instrument Transformer
Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.
-
product
Isolation Transformers 230V
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
product
Automatic Instrument Transformer Test Set
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
product
PC104 MIL1553A & MIL1553B Board
MS 1701
*Bus Interface - Standard ISA Bus (PC104 Interface)*One Dual Redundant MIL-STD-1553 Channels, Enhanced Mini-ACE BC/RT/MT Architecture*A periodic message insertion, Real-time bus playback with RT edit mode*Highly Autonomous Bus Controller Architecture, Message Scheduling*Bulk Data Transfers, Data Block Double Buffering*Asynchronous Messages, Retries and Bus Switching*Transformer or Direct Coupled 1553B Channels
-
product
Force Tensiometers
Sigma 702ET
The Sigma 702ET Transformer Oil Analyzer has been specifically designed to guide the user through the measurement of interfacial tension of transformer oil according to relevant standards.
-
product
Standard Current Transformers
Measurements International Ltd.
Single Range, Highest Permeability, Wide Measurement Range, Negligible Current Errors, High Accuracy.
-
product
Potential Transformer Test Set
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.