Filter Results By:
Products
Applications
Manufacturers
Safety Jacks
Socket whose insulating jacket meets safety standards.
- LBA Group, Inc
product
RF Safety Monitoring
MVG EME Guard XS 40GHz
EME Guard XS 40 GHz has been specifically designed to cover the new 5G millimeter wave bands. This RF safety tool is important for keeping those working close to RF emitters safer. It is easy to use, continuously scanning electromagnetic waves, and alerts the user when acceptable pre-selected limits have been exceeded.
-
product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781028-01
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
product
Magnetizer
350B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-02
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781209-01
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
product
Magnetizer
340B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
Magnetizer
330B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
779521-01
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-01
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
Air Force
Alpha 4314 AF
4314AF introduces an added safety feature that prevents the possibility of having the charging adapter connected while using the instrument for measurements. A 6-pin Mil-Spec circular connector on the front panel of the 4314AF replaces the four-terminal banana jacks and the battery charger jack. Four of the front panel connector pins are used to mate with the measurement adapter cable and the other two pins are for the battery charging cable adapter. By using separate adapter cables for measurements and charging of the batteries, it ensures that the charge circuit cannot be activated at the same time as measurements are being made.
-
product
Deluxe DMM w/Amp Shutters
582
*Huge 2 inch LCD Display, easy to see from across the room *Display is backlit for use in Dark Spaces *Amp Shutters prevent mistaken operation, improve safety and saves fuses by blocking unused amp jacks! *Great Meter for Electrical Trouble Shooting *11 Test Functions, 33 Test Ranges *Measures Temp in Both F and C, Probe Included *Desireable 20 Amp Test Range *Modern Design, the Protective Holster is Built-In *Data Hold *Carrying case, Test leads, Temp probe, Instructions and Battery included
-
product
High Voltage Switching Systems
HXV Series
HXV products are high voltage systems intened for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Stand HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2x4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banaba jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.
-
product
IEC61032 Test Probe Pin
CX-112
Shenzhen Chuangxin Instruments Co., Ltd.
1. Jointed test finger probe (Figure 2 / Test Probe B / IEC 61032)This is a precision probe made in accordance with all IEC standards. Examples are IEC 61032, 60950, 61010 and 60601; and it is also used for Canadian and USA standards. It features a palm simulator and a restricted joint movement, which simulates the characteristics of the human hand. The finger is made of stainless steel and the rest of the instrument is Delrin®. Handle is designed to accept either a banana jack or a force gauge.It is no longer necessary to have a separate probe for the medical safety standard. This one probe will meet all the different requirements that are in the IEC standards.
-
product
Magnetizer
345B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
Power Control
Educated Design & Development, Inc.
As a general purpose dual-voltage isolation transformer for step-up (120 to 240 VAC), step-down (240 to 120 VAC), or straight 1:1 isolation (120 to 120 VAC or 240 to 240 VAC). Models with a suffix "UC" are provided with a safety jack for access to the transformer secondary center tap (connected to the transformer center tap only in the 240 VAC output setting). This connection may be used in conjunction with a Dielectric Voltage Withstand test.
-
product
Safety
Test Equipment to verify Safety, Quality and Compliance characteristics of electro-technical products as required by national and international safety regulatory agencies. These equipment are used to check Electrical Wiring Accessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Several of these safety test equipment are common to many standards and are required for routine 100% test purposes to ensure product safety.
-
product
Safety Testing
Mobile Power Solutions specializes in guiding your company through today’s increasing quagmire of battery-related safety regulations. MPS provides comprehensive regulatory compliance, safety, and performance testing; we are ANAB accredited to ISO/IEC 17025:2017.
-
product
Safety Control Unit
Epec SC52
SC52 offers a flexible solution for software-based safety function implementation. Together with the SC52 controller, Epec offers a set of pre-certified PLCopen application libraries in order to reduce customer’s safety related software development effort.
-
product
Safety Testing
KTL Safety Group is fully accredited to meet the growing needs for worldwide safety testing and compliance and provides: Safety testing and certification of electrical and electronic equipment to international and European safety standards, Pre-compliance evaluations that identify problem areas early in the design stage, to reduce the need for potentially expensive modifications.
-
product
Product Safety Testing
NCEE Labs is an A2LA Accredited product safety compliance testing lab. We specialize in compliance testing to US and harmonized international standards. NCEE Labs also offers NRTL testing services. With experienced product safety engineers, we provide expert assistance, whether evaluating early prototypes or assisting with aftermarket design changes.
-
product
Digital Safety Tester
Is equipped with a high-efficiency PWM amplifier, which isolates the influence of external voltage fluctuations and outputs stable high voltage. Even in areas with large voltage fluctuations, it can achieve "safe" and "reliable" measurements.
-
product
Safety Tester
Safety analyzer is mainly used to provide the test solution for electric car, grid, photovoltaic, electrical appliances, information equipment, medical equipment industry as well as innovative solutions for the various electrical measurement.
-
product
Safety Analyzer
SA-2000
The BC Biomedical SA2000 Features: AAMI Load Earth / Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
product
Safety Light Grids
*Type 4 (IEC 61496) safety light curtains at Type 2 pricing*Reliable protection of hazardous areas*Industry standard M12 connection for simple wiring*Versions for the use in high pressure cleaning applications*Versions with active /passive system
-
product
Electrical Safety Testers
.AC/DC withstand voltage test & ground bond test .Insulation resistance test(ST60).Arc detection.Zero crossing turn-on,turn-off operation switch.Controllable ramp-up time .Ture RMS cut-off current measurement .Automatic fail indicator of alarm lamp and buzzer.VFD display.Standard PLC interface .Option RS-232,RS-485
-
product
Electric Safety Tester
PV-215
The multifunction device PV-215 allows quickly and safely carrying out the electric safety tests provided for a PV system (section in DC) and the functional test of modules/strings the system consists of according to the requirements of Standard IEC/EN62446.
-
product
Safety Camera Systems
Safety camera systems from SICK are electro-sensitive protective devices based on image processing technology. Sender and receiver are integrated into a single housing. The compact camera systems do not require any additional software and can be commissioned at the push of a button.Automatic alignment makes for high flexibility when defining the protective field. and the high degree of freedom in the machine design optimizes ergonomics for the operator.
-
product
Safety Testing
Seaward's high quality electrical safety testing equipment has a worldwide reputation for technical excellence in the appliance, electrical and electronics manufacturing sectors.
-
product
Safety Products
Contrinex sensor spacers, mounting brackets, column accessories, light curtain extenders, and more.
-
product
Safety Analyzer
SA-2000-INTL
The BC Biomedical SA-2000-INTL Base International Unit Model Features: Same as US BC Biomedical SA-2000 Model, but for users who need a power cord to meet their International Power Needs AAMI Load Earth/Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.