Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI 1A Fault Insertion Switch 22-Channel
40-195-001
The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.
-
product
Multifunction Installation Tester
COMBI519
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-20M
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Current measurements for small DC motor*Convenient +5V single polarity power supply
-
product
Fault Passage Indicator for Lines
LineTroll R400D
LineTroll R400D Fault Indicator indicates earth- and short-circuit faults and can distinguish between permanent and transient faults. The indicator has two sensors and use both the electrical field and the magnetical field to detect faults on all three phases.
-
product
Electrical Safety Test Equipment
Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.
-
product
Multifunction Instrument
COMBI521EV
COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Surge Voltage Generator
SSG 500
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
product
Current Clamps and Sensors
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
product
Loop Testing
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Detector of Earth Faults on Multi/Single-Core Terminations
CableTroll 2320
CableTroll 2320 is an indicator for detection of Earth faults (PtG) and short circuit (PtP) faults on multi-core and single core cable terminations. The unit uses NorTroll type current sensors.
-
product
Detection of Earth Faults (PtG) and Short Circuit (PtP) Faults
CableTroll 2330
CableTroll 2330 is an indicator for detection of earth faults (PtG) and short circuit (PtP) faults on multi and single core cable terminations. The unit uses NorTroll type current sensors.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
Earthing Resistance Tester
JYD-10A
transformer neutral grounding resistor is the vital need in medium voltage AC distribution network that are also called by different names like Neutral Earthling Resistors. They are taken into use to limit the current that would flow through the neutral point of a transformer or generator in the event of an earth fault. They are also used for resistance grounding of connected generators and transformers.
-
product
Multifunction Tester
EASYTEST
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
20Hz Generator
Signals & Systems India Private Limited
In order to implement a 100 % stator earth fault protection based on subharmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the Band Pass Filter SBPF-1001 in the Stator Earth fault protection. The injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.
-
product
Relay Test Set
Cambridge Instruments & Engineering Co.
“CIE” Relay Test Set is ideal for Testing Protective relay, over current relay, earth fault relay by secondary injection method with help of digital timer.
-
product
RCD Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD triggers. The tripping time is also measured. These two parameters, tripping current and tripping time, are the safety-relevant parameters of an RCD. The various selectable test currents and characteristics that can be set with this device make the PeakTech 2710 the ideal companion for every electrician.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
High Impedance Busbar Differential Relay
MIB
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
product
Loop Impedance Tester
CZ20054
Australian and New Zealand standards mandate testing of fault loop impedance on circuits not protected by RCD's, both at installation and after maintenance. The CZ20054 Loop Impedance Tester conducts earth fault loop impedance and prospective short circuit current (PSC) tests. The Aegis Loop Impedance Tester takes the confusion out of loop/psc testing by providing an automatic wiring check upon connection and single button operation.
-
product
Earth Fault Detector
K-3838
Kongter Test & Measurement Co., Limited
Kongter’s K-3838 earth fault detector is the updated model which is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the reliability of your electrical equipments. Our unique technique makes it safe and fast to handle earth fault in DC systems that are working online.
-
product
DC System Earth Fault Detector
PDF1000 / 781
Wuhan Huatian Electric Power Automation Co., Ltd.
Our company's DC system grounging fault tester is a new generation of products. It can be applied to dc system measurement of any voltage level.
-
product
Ground Earth Resistance Tester
2678X
Shenzhen Chuangxin Instruments Co., Ltd.
Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.
-
product
Ground Fault Locator
K-3837
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-20MH
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Convenient +5V single polarity power supply
-
product
Earth Fault Indicator
The Sensorform Range of Earth Fault Indicators detects earth faults & short circuit faults on underground cables. A number of options are available for enclosure type, power source, indicator type, reset method, trip-level selection, and remote indication.
-
product
20Hz Injection Kit Monitoring System
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
product
Earth Tester
TAURUS PRECIOHM ET
The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.
-
product
Detector of Earth Faults on Multi/Single-Core Terminations
CableTroll 2310
CableTroll 2310 is an indicator for detection of earth faults (PtG) on multi-core and single core cable terminations. The unit uses NorTroll type current sensor (CT)