Filter Results By:
Products
Applications
Manufacturers
Current Shunts
Resistors with known accurate values to measure current.
See Also: Shunts, AC Current Shunts
- Taylor Dynamometer, Inc.
product
311 HP Eddy Current Chassis Dynamometer
CM-51SR-EC
Weight Capacity: 25,000 lb (11,340 kg) per axleRoll Brakes: pneumatically-actuated discShipping Weight: 5,100 lb (2,312 kg)Capacity: 311 hp at 45 mph (232 kW at 72 kph)Rolls: 20 by 36 in. (508 by 915 mm) long, 2 fixedPit Required Depth: 25 in. (635 mm)
-
product
Shunts
WSM alternating current measuring resistors have compared with traditional direct current shunt resistors with coaxial voltage tap significantly better high-frequency transmission characteristics. This resulted from a production engineering very complicated structural design of the active part.ISM pulse current measuring resistors allow the metrological recording of the time curve fast current changes large amplitude in the nanosecond range. The ISM are designed for the pulse current measurement with broadband oscilloscopes.
-
product
Phase Meter Current Shunts
610 and 650
Clarke-Hess Communications Research
The Model 610 and 650 Current Shunts are specifically designed to operate with the Model 6000A Precision Phase Meter. These shunts are frequency tuned to have negligible phase shift (less than 5m) at 50/60Hz making them ideal for line frequency applications. They can also be idealized for other frequencies as specified by the user. Consult factory for details.
-
product
Working Standard Shunts
CSW
CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.
-
product
Precision High Current Resistors/Shunts
Measurements International Ltd.
The precision high current shunts are a series of High Current Resistors ranging from 1 A to 3000 A with optional air moving fans and resistance values from ohms to micro-ohm.
-
product
Current Shunt Module
CURS100
The CURS100 converts a current signal output by a sensor or output device (e.g., 4 to 20 mA) to a voltage that can be measured by a datalogger. The 100 ohm resistor used for the current shunt allows currents up to 25 mA to be read on a 2500 mV range (CR10, CR10X, CR510, CR500) and currents up to 50 mA to be read on a 5000 mV range (CR23X, 21X, CR7, CR5000, CR9000, CR9000X).
-
product
Micropower Voltage References
Analog Devices offers a broad line precision micropower voltage references with extremely low quiescent currents (series references) or minimum shunt currents (shunt voltage references). All of our precision voltage references offer excellent initial accuracy and low temperature drift over time and temperature. Our Reference Plus products combine precision voltage references with comparators or amplifiers.
-
product
Transconductance Amplifier
1620A
The 1620A provides high accuracy current levels from dc to over 10 kHz for calibrating ammeters, current transformers and shunts. It also provides output current up to 100 Amperes and as such may also be used as a high accuracy power supply, and as a power source in welding and bonding applications.
-
product
DC Power Analyzer, Modular, 600 W, 4 Slots
N6705C
The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software
-
product
Multiphase Power Analyzer
2800 Series
The Valhalla Scientific 2800 High-Precision Power Analyzer is available in 1-, 2-, 3-, 4-, 5-, or 6-phase versions. All voltage inputs 0.3V up to 1500V peak and all current inputs 1.5mA up to 1A; 15mA up to 5A; 1A up to 40A; and shunt inputs 60mV up to 6V are potentially free and exhibit low noise, high common mode suppression, excellent DC-stability, wide frequency range (DC-2MHz) and very low self-heating on current inputs.There is no need to fiddle with DC-compensation, or changing current plugging. All is built into the input sections of the power analyzer, ready for measurements. It is simple to use, your intuition will guide you to operate the Power Analyzer touch screen correctly.
-
product
Data Acquisition Recorders & Loggers
DAS1800
The DAS1800 can be configured for a wide variety of applications with slots for 10 input modules each supporting 4 or 8 measurement channels. Acquire data from any sensor with a voltage or current output (with shunt), or directly measure voltage, resistance, or temperature using thermocouples or resistance temperature detectors (RTDs).
-
product
Precision AC/DC Current Shunt
1625A
The BLI 1625A is a multiranging, high accuracy, active current shunt, for use in making NIST traceable measurements of currents from 10 microamperes to 100 Amperes. Very high measurement stability has been achieved in our shunt design by using special alloys, compensated by a proprietary Ballantine process to minimize temperature coefficient effects.
-
product
PXI Based Multifunction Measurement and ICT Instrument
PXI-501
The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.
-
product
Shunt
Shunts are used with Moving Coil Ammeters for the measurement of current in DC Circuits.
-
product
Wide Angle Scale Instrument
LS-96
Standard Electric Works Co., Ltd
● For ranges higher than 20A DC, use external shunt with a 50mV DC Ammeter.● For ranges higher than 300V DC, use external Volt Divider with a 1mA Voltmeter.● For ranges higher than 5A AC, use external Current Transformer with a 5A AC Ammeter. ● For ranges higher than 600V AC, use external Potential Transformer with a 150V AC Voltmeter.● Full Scale Deflection : 250° ● Accuracy : Class 1.5● Composition : Glass window, ABS resin frame and case, PC glass fiber base mounting fittings included.● Color : Black base and frame, white scale plate and meter body.● Pointer : Stick shape in black color.
-
product
Cross Voltage Testers
designed to perform the 60 Hz power line cross test/AC power fault tests required in GR 1089 issue 6 table 4.5 surge test 3,4, 4.3,and 6, and for UL 1950 section 6.4 paragraph 3 and 4.. Preset and Adjustable Time Settings Measuring Terminals including Voltage Sense and Current Shunt portals provide a safe location for users to accurately measure test voltages and output current while setting up tests. Calibration of the Mini_PT-600 is designed to be performed with a simple handheld multi-meter and the removable Currents Shunts can be easily sent to a calibration laboratory if required.
-
product
High-Voltage Isolation Amplifier
Knick Elektronische Messgeräte GmbH & Co. KG.
Measurement of DC or AC voltages up to () 3600 V and of large DC currents to about () 20 kA with shunt resistor or directly in the device to () 5A DC and AC. Variants with calibrated range selection.
-
product
DC Current Shunts
DC current shunts / standards are true 4-terminal devices that precisely measure DC currents from 10 A to 10,000 A. They use special alloys in the resistive elements which are supported on an insulating base for mechanical stability. The 9230A includes special features to reduce the effects of power dissipation and associated self heating errors. These shunts are designed to operate in air at full rated current. These are the best performing, and most widely used, DC metrology shunts in the world.
-
product
Shunt Isolation Amplifier
Knick Elektronische Messgeräte GmbH & Co. KG.
Especially to accurately measure large DC currents via shunt resistors, ie for making isolated detection of mV voltage on shunts. Variants with calibrated range selection. Working voltage up to 3600 V AC / DC.
-
product
Series Voltage References
Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.
-
product
Electrical Standards
To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.
-
product
Current Probe
DCP-BTA
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
product
DC Electronic Loads
Keysight DC electronic loads provide you with the flexibility to test a wide range of applications from power-supply test to simulation of high-intensity discharge (HID) headlamps. The 16-bit voltage, current and power-measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.
-
product
Shunt Assembly
RSA-8
The RSA-8 Recording Shunt Assembly contains 8 individual shunts with terminal block programming for either a current channel (using the shunt) or bypassing the shunt and using a dropping resistor for conversion to a voltage channel.
-
product
Shunts
Highly accurate manganin resistance d.c shunts. When a current is passed through the shunt a proportional millivolt output is produced.
-
product
High Current Calibrator
MC151
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
product
20V/30A/300W DC Programmable Electronic Load
TOB-IT8512
Xiamen Tob New Energy Technology Co., Ltd
IT8512 120V/30A/300W DC Programmable Electronic Load for Battery and Power Supply TestHigh performance and affordable single channel DC electronic load. TOB-IT8512 DC electronic loads provide you with the flexibility to test a wide range of applications from power supply, charger to battery. The high resolution voltage(1mV), current(0.1mA) measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.
-
product
Digital Power Meter, 30A
66205
Chroma Systems Solutions, Inc.
Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface
-
product
Dual Wide Range Power Monitor
LTC2992
The LTC®2992 is a rail-to-rail system monitor that measures current, voltage, and power of two supplies. It features an operating range of 2.7V to 100V and includes a shunt regulator for supplies above 100V. The voltage measurement range of 0V to 100V is independent of the input supply. Two ADCs simultaneously measure each supply’s current. A third ADC monitors the input voltages and four auxiliary external voltages. Each supply’s current and power is added for total system consumption. Minimum and maximum values are stored and an overrange alert with programmable thresholds minimizes the need for software polling. Data is reported via a standard I2C interface. Shutdown mode reduces current consumption to 25μA typically.
-
product
Multi-Channel Digital Power Meters
66203/66204
Chroma Systems Solutions, Inc.
Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders
-
product
Load Cell Amplifier Signal Conditioner with Removeable Terminals
MODEL LCA-RTC
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.