Filter Results By:
Products
Applications
Manufacturers
Charge Plates
acts as a capacitor whose discharge is measured.
- Virginia Panel Corporation
product
Strain Relief Plate, Receiver/ITA, SIM, PCB or wired solutions
510109598
Strain Relief Plate, Receiver/ITA, SIM, PCB or wired solutions.
-
product
Walking Test System Kit
PGA-710
The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.
-
product
Collapsible 6 Inch Charge Plate Monitor Assembly
CPM-760A
- 6" x 6" (15 cm x 15 cm) conductive plate- Total system capacitance of 20 pF ± 2 pF- Meets the requirements of ANSI/ESD STM3.1 and ANSI/ESD SP3.3- Designed to perform audits on overhead ionizers and room ionization systems- Flexible to also evaluate and balance bench top ionizers- Completely collapsible for compact storage- Designed to be used with the PFM-711A and PFM-711B
-
product
Charge Plate Monitors
Our easy-to-use charge plate monitors allow you to accurately evaluate air ionization systems used to neutralize static charge accumulation. Benefit from our economical solutions and products that offer onboard data storage to automate ionization system testing.
-
product
Basic Field Kit
PFK-101
The PFK-101 includes the PFM-711B Electrostatic Field Meter, CPM-720B Charge Plate Monitor and PCS-730B ±1 kV Electrostatic Charger for measuring ionizer decay and balance.
-
product
Periodic Verification System for Measuring Static Charges and Verifying Ionizer Performance
STME-PVS
Statclean Technology (S) Pte Ltd
This meter is designed to measure static charges and to verify ionizer performance. It consist of three components- an Electrostatic Fieldmeter, a Detachable Plate and a Charger.
-
product
Autoanalysis System Set
PGA-710B
The PGA-710B is a unique electrostatic data analysis device for use with Prostat's PFK-100B Field Meter and Charge Plate Monitor kit. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions.
-
product
Ionization Test Set
PFK-105
- Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included
-
product
Charge Plate Monitor
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
product
Field Meter
EFM-022
• This electrostatic field meter EFM022 is a hand-held field meter for precise measurement of electrostatic charges.• With the CPS022 accessory, the electrostatic field meter can be used as a charge plate monitor.• Precise measurement of static charges with automatic distance conversion (choice of 5 pre-set distances)• Operates on battery that can be supplemented with an AC net adaptor• With optional CPS022, can be used as a charge plate monitor for audit purposes and checking of ionization appliances
-
product
Electrostatic Discharge
Our electrostatic discharge (ESD) measurement and control solutions include charge plate monitors, sensors, resistivity meters, and voltmeters. Reliably monitor, measure, locate, and test for static electricity.
-
product
Electrostatic Field Meter - Hand Held Field Meter for Locating and Measuring Electrostatic Field Density
PFM-711B
- Lightweight, portable, hand-held Field Meter- Measure in 1 volt/in increments 0 to ±1,999 Volts- Measure in 10 V/in increments 0 to ±20,000 VoltsAccuracy of <±5%- LED ranging lights help position the meter at the right distance- Zero button allows the display to be adjusted to zero (0)- Hold feature freezes the measurement on the display- Use with Prostat CPM-720B Charge Plate Monitor and PCS-730B Electrostatic Charger- Use with Prostat PGA-710B AutoAnalysis System or X-Y Plotter- Analyze Footwear/Flooring Combinations- Verify Ionizer Balance and Decay Time Performance- 2-year Limited Warranty (1 year on the sensor)
-
product
3-Component Quartz Force Rings
260 Series
Three-component quartz force ring sensors are capable of simultaneously measuring dynamic force in three orthogonal directions (X, Y, and Z). They contain three sets of quartz plates that are stacked in a preloaded arrangement. Each set responds to the vector component of an applied force acting along its sensitive axis. 3-component ring force sensors must be statically preloaded for optimum performance. Preloading provides the sensing elements with the compressive loading required to allow the proper transmission of shear forces. Versions are available with ranges up to 10k lb (45k N) in the z-axis (perpendicular to the top surface), and up to 4000 lb (18k N) in the x-and y (shear) axes. Both ICP® and charge output styles are available.
-
product
Electrostatic Products
We offer electrostatic measurement instruments for electrostatic discharge (ESD) and high-performance applications. Select from our reliable electrostatic sensors and detectors, voltmeters, charge plate monitors, and surface resistance/resistivity meters.
-
product
Charge Plate Monitors
Our charge plate monitors the voltage of the battery and the voltage of the battery.
-
product
Charge Meter
NK-1001A/NK-1002A
Probe-type charge meter that can easily measure the amount of discharge charge that causes static electricity destruction in the manufacturing, inspection, and assembly processes of electronic devices.Many ESD phenomena that impair electronic devices are represented by the CDM ( Device Charging Model). The CDM is a model that represents a phenomenon in which a high peak current flows at high speed when the device itself is charged and its external electrode is grounded. The coulomb meter measures the amount of discharge charge, which is the integral value of the current, with high accuracy.
-
product
Periodic Verification System
Model 775 PVS
The Simco-Ion Periodic Verification System Model 775PVS is a hand-held alternative to a charged plate monitor. It consists of three components-a fieldmeter, a detachable plate, and a charger for measuring static charge and verifying ionizer performance. Used alone, the fieldmeter measures electrostatic fields on any surface.
-
product
Charge Integrator Amplifiers
AD8488
Analog Devices’ charge integrator amplifiers convert the charge acquired by X-ray or photodiode detectors to a voltage. The channels are composed of CMOS transistors, using typical high input impedance CMOS gates. The integrators generate charge dependent voltages using a range of selectable capacitance values that accommodate a broad range of input charge values. The integrators are followed by single-ended input to differential output voltage amplifiers where offset and low frequency noise voltages are subtracted from the input voltages.
-
product
Adapter Plates
ARINC 791 compliant adapter plates simplify and standardize antenna and radome installations by providing commonality and interchangeability across entire fleets.
-
product
Thermal Image Plates
No longer are the firebricks and smoldering paper "tools of the trade" for researchers working with CO2 lasers. Now it''s possible to see IR laser beams in real time and with high resolution using a Thermal Image Plate from Macken Instruments. The characteristics of this instrument enable it to solve a wide range of problems. For example:
-
product
In-Line Charge Amplifiers
The in-line charge amplifier is used to excite structures or machinery with a definable impulse force. Resonances are identified by impulse, an important measurement parameter for the study of dynamic behavior. The 4705A1 is a fast turn on time, 50 mV/pc, in line charge amplifier with BNC jack connectors on each side.
-
product
Charge Sensitive Preamplifier-Discriminator
A101
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
product
Plate Rheometer
DVNext Cone
The DVNext Wells-Brookfield Cone/Plate Rheometer is a precise torque meter which is driven at discrete rotational speeds. The torque measuring system, which consists of a calibrated beryllium-copper spring connecting the drive mechanism to a rotating cone, senses the resistance to rotation caused by the presence of sample fluid between the cone and a stationary flat plate.
-
product
Accelerometer (Charge Output Type)
NP-2000 Series
This sensor converts mechanical vibrations into electric signals in proportion of vibration acceleration.You can choose the one that is ideal for your purpose,conditions,applications etc. from wide variety of selection.Charge amplifier is necessary because it is a charge output type,however, compared to pre-amplifier built-in type, it can be used at higher temperature in general.
-
product
Force Plate Logger Sensor
NUL-225
This module is in fact a weight scale designed for a multi range of purposes. Simply lay a heavy weight on its surface, or activate a forceful pressure against it (like a bouncing ball), and the logger sensor will measure it. But that's not all, once a special set of handles are attached, it can also measure pull pressure rather than just weights and presses.
-
product
Power Switches With USB Charge Controller
ST’s USB charger emulator family (STCC) features ICs integrating a power switch, a data switch and an intelligent charge controller. It supports most charging schemes on the market (standard and proprietary) to ensure compatibility with a broad range of portable devices. ST’s unique and patented attach detection mechanism makes the STCC family ideal to guarantee fast and accurate charging while preserving the host battery.
-
product
Charge Converter
CH-6130/6140
The CH-6130/6140 charge converter is a simplified type of charge amplifier converting charge signal to voltage.It can be connected directly to an input BNC connector of a CCLD applicable equipment such as FFT analyzer or vibration comparator, enabling direct connection of a charge output pickup without suing a box type amplifier.
-
product
Adapter Plate, 9050 Enclosure to 9025 ITA
410112422
This Adapter Plate allows a 25 Module ITA to accept standard 50 Module Enclosures.
-
product
16 Channel Charge Integrating ADC
CQ16
The CQ16 is a 16-channel 12bit, fast converting charge-integrating ADC for CAMAC. To provide compatibility to older CAMAC ADC’s it can be switched into an 11-bit mode. All data read-out is provided either via CAMAC commands or through the fast FERA bus on the front of the module.
-
product
Charge System Safety
Renesas' charging system safety circuits are optimized to provide a redundant safety protection to an Li-ion battery charging system by monitoring input voltage, battery voltage and charge current.