- Pickering Interfaces Inc.
product
PXI 10 Banks of 8 Channel 2 Pole MUX
40-615-022-10/8/2
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
Resistive & Capacitive, Inductive AC Load Bank
RLC
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
-
product
Resistive & Inductive AC Load Bank
RL
Resistive & reactive load banks are able mimic motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit. JUNXY has an extensive range of resistive & reactive load banks to simulate these types of loads on a power source and the transformers, relays, and switches which will distribute the power throughout your facility.
-
product
Inductive Load Banks
L-Series
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
product
AC Load Bank (Resistive/Reactive)
K-1000 Resistive/Reactive
Kongter Test & Measurement Co., Limited
Resistive/reactive load banks are great choices for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others. A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage.
-
product
Load Bank
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
product
Resistive Load Banks
R Series
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
product
AC Load Bank (Resistive & Inductive)
K-1000 Resistive & Inductive
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
product
Anti-Islanding Load Banks
AI-Series
AI-series anti-islanding load banks containing purely resistive, inductive, or capacitive load, have segmented combination control of power input, and can simulate a variety kinds of power loads to meet the grid-connected inverter full load test requirements.
-
product
Load Module for SLSC
Bloomy's 8-Channel Load Module provides isolated current and voltage measurements for eight on-board 5W loads or for eight off-board 120W loads. With built-in switching for calibration and fault injection, the module provides unsurpassed capability for Mil/Aero applications. The module also provides switching and connections to allow switching between a real load (e.g., actuator, valve, etc.) and the simulated load.
-
product
Load Board
cPCI 3U
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
product
Load Board
cPCI 6U
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
product
Load Board
cPCI Serial 3U
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
product
PXIe-4051 - PXIe, 1-Channel, 60 V, 40 A PXI Electronic Load Module
788179-01
The PXIe-4051 provides programmable load capable of sinking DC power for characterization, design validation, and manufacturing test. This module helps you sink current and absorb power out of a power source up to 300 W with programmable constant voltage, current, resistance, and power levels. You can use the PXIe-4051 to streamline the task of designing automated test systems for a wide range of applications—from aerospace and defense to automotive and semiconductor component test—by eliminating the need to mix multiple instrumentation form factors in a given test system and simplifying synchronization.
-
product
AC Load Banks
X60C Series
Mosebach Manufacturing Company
The X60C is a small suitcase style 60 kW load bank.
-
product
AC Load Banks
X250S Series
Mosebach Manufacturing Company
The X250S is the only one of its kind: 250 kW in a very small package. Light, portable; with digital meter and recording capability. Center lifting bar and casters are both available as options. Ideal for "Black Tests" in data centers as blowers are powered externally with 120VAC
-
product
AC Load Banks
K-1000 Series
Kongter Test & Measurement Co., Limited
Load bank testing is vital to replicate and verify the operation of critical backup power systems such as diesel generators and uninterruptible power supplies (UPS). Kongter offers a wide range of customer-tailored AC load banks that excel in a range of load test applications and environments.
-
product
Load Banks
BD Series
*12 kW, 15kW and 18kW Battery Discharge Load DC*All of our Load Banks are continuously rated for Power and Current.
-
product
DC Load Bank
K-900
Kongter Test & Measurement Co., Limited
K-900 series are your best choice DC load bank with Kongter’s updated solutions. This new series resistive dummy load includes a series customized load bank models that feature rugged design and and excellent performance. They facilitate your work for DC load and battery capacity testing. With different models of DC load bank, it covers a wide range from 12V to 480V nominal voltages with current up to 600A. Its big TFT touch screen with vivid display makes it more user-friendly for setting and operation. Kongter’s new PC software make it easy for measurement monitoring and report print out.
-
product
Load Banks
EL08 Series
*Rectifier Test 8kW*All of our Load Banks are continuously rated for Power and Current.
-
product
Radiator Mounted Load Banks
RD-Series
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
product
AC Load Banks
Power House Manufacturing, Inc.
Hand carried AC load banks in any capacity to meet your load testing needs. Power House Manufacturing has developed the best ultra-compact and light-weight hand carried AC load banks. AC load banks with capacities unmatched in the industry.
-
product
Unclamped Inductive Load Tester
ITC55600C
Model ITC55350 is the high current (600A) version of theITC55100 tester. The ITC55350 performs the same testsas the ITC55100 and includes many features that improvetesting accuracy, test results collection, test resultsviewing, and multiple tester networking
-
product
Unclamped Inductive Load Tester
ITC75100
The ITC75100 is an enhanced unclamped inductive load (UIL) test system that builds on the success of ITC’s industry leading ITC55 series of testers by adding additional test and measurement capability.
-
product
AC Load Bank
AC-LB-Series
Eagle Eye AC Load Banks are commonly used for testing generator sets, UPS units, aircraft power inverters and other government and military AC power sources. The Eagle Eye AC LB-Series is the smallest in the industry and offers unmatched durability in even the harshest testing environments. Eagle Eye offers several standard models as well as custom AC Load Banks.
-
product
Custom Load Banks
Power House Manufacturing, Inc.
Custom Load Banks are our specialty. Power House Manufacturing is dedicated to providing our customers with exactly what they need. Having years of custom load bank manufacturing experience, Power House can deliver the perfect custom testing solution you require.
-
product
Resistive AC Load Bank
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
product
Inductive Sensors
Inductive sensor designed to detect shaft speed, shaft position, gate position, or object presenceTotally sealed constructionMulti-voltage 24 - 240 VAC/VDCDetects ferrous targets up to 5/16" (8 mm)IP 65 Protection
-
product
Inductive sensors
Inductive sensors are signal generators which detect function-related movements of processing machines, robots, production lines, conveyor systems etc. in a contactless fashion, and transform them into electrical signals.
-
product
AC Load Banks
X100L Series
Mosebach Manufacturing Company
Introducing Mosebach’s X100L load bank. One of the lightest dual voltage, 100 kW load banks on the market! The unit weighs approximately 64 lbs. and has 5 kW resolution. The X100L load bank includes an Industrial strength, injection molded, 100% water proof case with wheels as shown below.
-
product
Load Banks
PARELO
Amfax introduce the latest generation of load banks we affectionately call PARELO. This range of load banks provides a combination of high performance passive resistive loads along with extreme flexibility of use. This is achieved by our unique FLEXI-phase Switching(TM) technology.. Designed primarily for offering high wattage loads for the aerospace, energy, automotive and transport sectors. PARELO load banks are a cost effective solution for companies requiring high wattage loads when testing their products.