Filter Results By:
Products
Applications
Manufacturers
Integrating Spheres
Uniformly scatter or diffuse light rays.
See Also: Goniophotometers, Spectroradiometers
-
product
Reflectance/Transmittance Test Set
RT-500
An Integrating Sphere is a hollow sphere which has its interior coated with a paint that is nearly perfectly diffuse or Lambertian and which has extremely high reflectance. Light energy introduced in an integrating sphere is reflected from the wall and distributed uniformly around the interior. A detector which is placed at a hole or 'Port' in the sphere wall sees an output which is completely independent of the angularproperties of the input light. The independence of the output of a sphere from the angular properties of the input and the uniform internal distribution of light make integrating spheres ideal for many uses.
-
product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Integrating Sphere Coating
SP-80
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. A good internal coating is essential forintegrating spheres. It is a special water based BariumSulphate (BaSO ) white reflective paint particularly suitablefor internal coating of Integrating Spheres. It offers an almost constant reflectance in the range of 380 nm to 780 nm (visible wavelength range).
-
product
Photometric Testing Services
LLI. offers a wide variety of services to fulfill your photometric, color and electrical testing needs. Using our custom, rotating mirror, Type-C goniophotometer, in combination with various integrating spheres, we are able to test many different types of lighting fixtures and light sources. LM-79 -08 Test & LM-80 Test, SSL Photometry Testing, Energy Star®, CEC Title 24, DesignLights Consortium® (DLC), Custom Tests and UL / ETL Safety Test Consultation.
-
product
Integrating Sphere FT-NIR Spectrometer
QuasIR 3000™
The QuasIR™ 3000 was designed from the ground up to offer the industry a new kind of NIR analysis solution – a solution that brings together the portability required to move NIR analysis closer to point-of-need, combined with unmatched spectroscopic performance for the fastest and most accurate results.
-
product
Reflection Meter
RC-088
This instrument is a special equipment for measuring the reflectivity of rearview mirror (or similar product) of motor vehicle. The product composes intelligent measuring instruments, optical integrating sphere, parallel lamp, standard light source, constant current source etc. It is easy to operate,it can measure the reflectivity quickly and accurately. On instrument structure, it adopts standardized modulation design. It takes latest single chip as its digital central processing element. After the measuring signal is converted by modulus, CPU will do some computation and compensation. The instrument can display the reflectivity of device which is measured in rear time. It operates simply and quickly, the indication is direct and accurate. It’s good for quality examination &control in the production scene as well as laboratories. This product has the convenience &quick demarcation way, can meet requirement of different occasion. It is applicable for measuring light reflection on mirror and not mirror parts.
-
product
UV-VIS-NIR Spectrophotometer
UV-2600i, UV-2700i
The compact UV-2600i/2700i is a universal, research-grade spectrophotometer that can be used in a wide range of fields, and easily expanded to suit the measurement objective. By using the optional integrating sphere, the measurement wavelength range of the UV-2600 can be extended to the near-infrared region of 1400 nm. The UV-2700 is capable of 8-Abs measurements, and optimal for measuring low transmittance samples.
-
product
CAS-200 Compact Array Spectrometer
CAS-200
Hangzhou Everfine Photo-E-Info Co., LTD
CAS-200 can quickly and accurately measure the spectral power distribution in the range of 380nm ~ 780nm, mainly measuring: the relative spectral power distribution, chromaticity coordinate, color temperature, color rendering index, color tolerance, peak wavelength, FWHM, luminous flux (with integrating sphere) of traditional lamps/light sources, single LED, LED modules and other electric light sources.
-
product
General Purpose Integrating Spheres
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
product
Integrating Spheres & Absolute Flux Integrators
Photometric Solutions International Pty Ltd
PSI’s LF series integrating sphere photometers are widely regarded as excellent quality, robust equipment for industrial or laboratory applications.
-
product
Integrating Sphere With Holder Base
IS-*MA
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12, and all kinds of luminaries2. The hold base can be installed in the ceiling or down, it can be adjusted the height3. Hold base has four power cables connect to the outside Power Supply and max is 5KW4. The holder base is detachable. For some kinds of light sources you may need to change the position of the holder base.5. Diameter: IS-0.3M (0.3m), IS-0.5M (0.5m), IS-1.0MA (1.0m), IS-1.5MA (1.5m), IS-1.75MA (1.75m), IS-2.0MA (2.0m). Other sizes can be designed according to the customer’s request.6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
IR/Visible Target Projectors
Santa Barbara Infrared’s reflective infrared and visible target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) and visible imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies, Infinity VSX Integrating Spheres and 300 Series Target Wheels.
-
product
Calibration Light Source
CAL1
Image Engineering GmbH & Co. KG
The one light source solution in the field of camera characterization and calibration. CAL1The CAL1 calibration light source is designed to characterize and calibrate cameras in the lab or on the production line. Its compact design consists of one iQ-LED element in a 0.3 m integrating sphere that illuminates a 70 mm opening. Because of the non-reflective special diffusor filter on the sphere opening, a uniformity of more than 98% could be reached
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Integrating Spheres
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
product
Light Analysis
Welcome to Thorlabs; below you will find links to detectors and instrumentation that measure the various properties of light, a subset of our entire line of photonics products. Thorlabs offers an extensive selection of instruments that measure the properties of light. Our versatile power and energy meters can be used with over 25 different sensors in order to make NIST-traceable power and energy measurements. If the convenience of a meter is not desired, our selection of detectors includes basic photodiodes (uncalibrated and calibrated), photodetectors (biased, amplified, and avalanche), CCD and CMOS arrays, position detectors, integrating spheres, and photomultiplier tubes. The Beam Characterization category contains beam profilers (camera and scanning slit), a wavefront sensor, spectrometers, and interferometers, while the Polarimetery link leads to a selection of instruments used to measure and control the polarization of light.
-
product
Integrating Sphere Spectroradiometer System for LED
LPCE-2(LMS-8000)
LPCE-2(LMS-8000) is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 127-1997 and IES LM 79-08 standards, it recommends using an array spectroradiometer with integrating sphere and photometer head to test SSL products. LISUN GROUP developed LPCE-2 test system for LED products.
-
product
Constant Temperature Integrating Sphere
IS-*MT
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Standard Light Source
SLS-50W
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
product
Integrating Sphere Systems
An optical device for various purposes such as. measuring the radiant flux (optical power) from a laser diode, light-emitting diode (LED) or bulb.
-
product
Conversion Kit for Kelvin Holders
KC-4
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
product
Transmission & Integrating Sphere FT-NIR Spectrometer
QuasIR™ 4000
The QuasIR™ 4000 was designed from the ground up to offer the industry a new kind of NIR analysis solution – a solution that brings together the portability required to move NIR analysis closer to point-of-need, combined with unmatched spectroscopic performance for the fastest and most accurate results.
-
product
Integrating Sphere
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
High Power Optical Head With Integrating Sphere
81628C
The 81628C High-Power Optical Head features an integrated sphere that enables it to handle power levels up to +40 dBm (with heat sink), across 800 nm to 1700 nm wavelength range. It provides the highest accuracy at high power within the family.
-
product
UDT-Series Integrating Sphere Systems
Gamma Scientific offers a variety of pre-configured integrating sphere systems for use in conjunction with the UDT line of optical meters, with both 25 mm and 150 mm diameters.
-
product
UV-VIS Spectrophotometer
UV-i Selection
UV-3600i Plus, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples.