Filter Results By:
Products
Applications
Manufacturers
- PalmSens BV
product
Potentiostat / Galvanostat / Impedance Analyzer
PalmSens4
PalmSens4, is a USB and battery powered Potentiostat, Galvanostat, and optional a Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS). The PalmSens4 has a large potential range (-5V to 5V or -10V to 10V) and current range (100 pA to 10 mA) with a high resolution and low noise. This instrument is a complete laboratory instrument but its compact and rugged design makes it also ideal for field work.
-
product
IDA Electrodes
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
product
Scanning Electrochemical Systems
The VersaSCAN is a single platform capable of providing spatial resolution to both electrochemical and materials-based measurements. Each VersaSCAN is based on a common high-resolution, long-travel, closed-loop positioning system mounted to a vibration-resistant optical base. Different auxiliary pieces are mounted to the positioning system. These ancillary pieces (e.g., an electrometer, piezo vibration unit, or a laser sensor) provide functionality to the positioning system for different scanning probe experiments. VersaSTAT potentiostats and Signal Recovery Lock-in Amplifiers are integrated via ethernet control to make accurate measurements of these small signals.
-
product
Weld Testers
The Weld Tester is our most versatile electrochemical monitoring instrument. Housed in a substantial metal case with brushed anodised aluminium front panel and green military specification connectors this equipment looks functional and professional. The top row of connectors are exactly the same as provided on a Gill 12 whilst the bottom row are for the additional weld segments. Using the same Potentiostat, Galvanostat, Zero Resistance Ammeter with integrated Frequency Response Analyser and Sweep Generator as a Gill 12 allows all the tests supplied with the Gill 12 to be supplied with the Weld Tester.
-
product
Oxygen Sensors, Analyzers and Accessories for Diving Products
PST are proud to be the preferred supplier of diving sensors to some of the most reputable rebreather manufacturers throughout the world.Here you will find replacement electrochemical oxygen sensors for all major brands and models of diving instrumentation devices.
-
product
Single Channel Potentiostats
VersaSTAT Series
This family of instruments combines our option-based hardware and software platforms to create the most popular line of potentiostats. Introduced for the majority of researchers doing typical electrochemical experiments, this entire series gained a key improvement in 2018. As of August 1st, 2018, all VersaSTAT models have ± 2 Amp capability standard. Users can now study larger samples at faster rates.
-
product
Impedance Spectroscopy
NuVant EZware-EIS Software Package
The NuVant EZware-EIS software package activates Electrochemical Impedance Spectroscopy on the EZstat-Pro, Powerstat-05 and -20 potentiostat/galvanostats. EZware-EIS exports the impedance data to a file format to accommodate free third party EIS analysis software. EZware-EIS is a user-friendly interface that allows selection of the proper scanning parameters, collect the impedance spectra, display data in Nyquist and/or Bode plots and export data in the proper data format for use in EIS analysis software.
-
product
The Golden STM
*Golden (chemically resistive) vibration isolated STM body with implemented preamplifier*Computer with PCI board based SPM controller *Anfatec Scan & Anfatec Present*19“ STM controller (extra low noise 24 bit converters)*HV display for z-direction*High voltage amplifiers for the x-y-tube scanning*Optional: PC controlled bi-potentiostat and electrochemical cell
-
product
Time-Resolved Electrochemical Quartz Crystal Microbalance
400C Series
The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).
-
product
Linear Polarization Resistance (LPR) Monitoring
The electrochemical technique, commonly referred to as Linear Polarization Resistance, is the only corrosion monitoring method that allows corrosion rates to be measured directly, in real time. Although limited to electrolytically conducting liquids, the response time and data quality of this technique make it clearly superior, where applicable, to all other forms of corrosion monitoring.
-
product
Temperature & Humidity Transmitter
HTO
Chuan Sheng Electronics Co., Ltd.
- CO2 measuring element: NDIR Sensor 2- CO measuring element: Electrochemical sensor- Temperature/Humidity sensing element : CMOS sensor- Analog output option:4~20mA or 0~10V- Communication output option:RS485 Modbus RTU- Configured by PC with free software via USB cable (option)- Present value offset adjustable- Inside buttons for adjust output parameters- LCD backlight color to Indicated CO/CO concentration 2- Temperature measuring range can be -50~100℃ via USB console port to setting
-
product
Electronic Loads
AMETEK Programmable Power, Inc.
Electronic loads have found a variety of applications ranging from power converter testing to current modulation. A large range of power sources can be tested using an electronic load from converters, inverters and UPSs to electrochemical sources such as batteries and fuel cells.
-
product
Trace Hydrogen Analyzer
GNL-400
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-400 trace hydrogen analyzer adopts imported high-performance electrochemical sensor with latest micro computer technology. It has such functions of LCD display, upper & lower alarm, signal output and relay contactor alarm output. And can be used to measure the hydrogen concentration in nitrogen, oxygen and argon.
-
product
Surface Insulation Resistance Testing
AutoSIR2™
One AutoSIR chassis can hold between 1 to 16 measurement cards and can monitor up to 256 x 2-point test patterns or 78 x 5-point test patterns, or 32 x 9-point test patterns at selectable intervals from minutes to days. Each channel is current limited (1 M Ω), ensuring that dendrites are preserved for failure analysis. The frequent monitoring capability provides a full picture of the electrochemical reactions taking place on a circuit assembly, and provides early trend analysis enabling tests to be curtailed, thus saving considerable test time and money.
-
product
Electrochemistry Research Equipment
Our electrochemical equipment will help your group achieve laboratory and research goals. The best-selling EZstat Pro potentiostat/galvanostat can run cyclic voltammetry, electrochemical impedance spectroscopy (EIS), battery tests, and high speed galvanostatic intermittent titration technique (GITT). The EZstat HV potentiostat delivers up to 1 amp at 25 volts. The Powerstat comes in two configurations (5 amp vs 20 amp). The Duostat bipotentiostat can operate rotating ring-disk electrode experiments. The Arraystat and ArrayPGstat feature multichannel operation with different customizable options (current range, number of channels, etc.).
-
product
Radiometer Analytical Probes
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.
-
product
Materials And Chemical Analysis
Anderson Materials Evaluation, Inc.
Materials characterization, failure analysis, quality control, and materials and process development services are offered. Our analytical techniques allow us to assess elemental and chemical material composition, thermal properties, coating thickness, electrochemical properties, surface chemistry, surface wetting, corrosion rates and pitting potentials, contamination and degradation problems, metallography, fractography, phase transitions, static coefficient of friction, adhesive bonding strength and causes of adhesive bonding failures, surface tension and surface energy, tensile and compressive strength, bend deflection, lapshear strength, elasticity properties, UV and visible light absorption and reflection, density and porosity, and many other material properties integral to improving your products.
-
product
Universal Converter
C8000
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
product
Gas Analysis
HPR-40 DEMS
The Hiden HPR-40 DEMS is a bench top or mobile cart mounted module for analysis of dissolved species in electrochemistry. The system is modular and adaptable. The system includes two differential electrochemical mass spectrometry ‘DEMS’ cell inlets, designed for material/ catalysis studies, cell type A, and electrochemical reaction studies, cell type B.
-
product
Automatic Defluxing System
Trident
Trident removes all contamination and residues from post-reflow circuit assemblies. When assembly and flux residues are removed, so is the chance for electro-chemical migration (ECM) failures. Clean assemblies are more reliable assemblies.
-
product
Pine Research Instrumentation
Known as a forefather in the development and production of electrochemical research equipment, Pine continues to support research and development activities worldwide through a family of vertically integrated resources represented by Pine Research Instrumentation. With a comprehensive team of engineering production, sales and support professionals Pine Research is well positioned to meet the industry's needs from its location in Durham, North Carolina.
-
product
Electrochemistry
Modular Line
The Modular Line of instruments consists of a range of instruments to suit any requirements in electrochemical research, from low to high voltage and from low to high current.
-
product
Electrical Resistance (ER) Monitoring
The electrical resistance (ER) technique is an "on-line" method of monitoring the rate of corrosion and the extent of total metal loss for any metallic equipment or structure. The ER technique measures the effects of both the electrochemical and the mechanical components of corrosion such as erosion or cavitation. It is the only on-line, instrumented technique applicable to virtually all types of corrosive environments.
-
product
Potentiostat/Galvinostat Electrochemical Instuments
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
product
Combo Gas Monitor
Z-Gard Combo Gas Monitor
A cost-efficient monitor for underground garages and ventilation control, the Z-Gard Combo Gas Monitor uses an electrochemical sensor to detect carbon monoxide. The unit features local audio/visual alarm status indicators and it can be configured to interface with air-handling equipment to control air quality within a building.
-
product
Single Channel Potentiostats
ModuLab XM ECS
ModuLab XM has modularity at the center of its design. Each system can be configured for electrochemical, materials, and photoelectrochemistry measurements. At the core of each of these is the Frequency Response Analyzer. The accuracy from design to calibration is at the heart of Solartron's success and reputation for impedance measurements.
-
product
Chloride Test System
C-CL-2000
The C-CL-2000 produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reaction of a weighted sample placed in an extraction liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight - is covered.
-
product
Addon Cards
Fit the IM6/Zennium electrochemical workstation to your application. Control external potentiostats, capture additional physical properties or enhance your system to a true parallel impedance analyzer.
-
product
Oxygen Sensors for Medical Products
USA manufactured electrochemical galvanic oxygen sensors (O2 sensors) for use in ventilators, anaesthesia machines, incubators, oxygen monitors and breathing gas mixes.Approved FDA, MDSAP, ISO13485, ISO9001 replacement oxygen sensors for respiratory medical devices with lifetimes up to 60 months. .