Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI 16-Channel 4-Bus 2A Fault Insertion Switch
40-197A-002
This 16-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers.
-
product
Ground Fault Analyzers and Detectors
The Model 760 detects and locates accidental ground faults on both energized and de-energized power circuits including single phase, three phase, and DC ungrounded systems.
-
product
PCI Fault Insertion Switch Range for Differential Serial Interfaces
50-200/201
Pickering Interfaces, a leading supplier of modular signal switching for electronic test and simulation, is expanding its range of PCI Fault Insertion switching with the introduction of two new modules (models 50-200 and 50-201) designed for use with differential serial interfaces. PCI Fault Insertion Switch Cards for Differential Serial InterfacesThe new modules include the Differential PCI Fault Insertion Switch (model 50-200) which is designed for lower data rate serial interfaces such as CAN and FlexRay, and the High Bandwidth Differential PCI Fault Insertion Switch (model 50-201) which is designed for higher data rate serial interfaces such as AFDX and 1000BaseT Ethernet. Each module allows the introduction of fault connections that include data paths open, data paths shorted together, and data paths shorted to externally applied faults such as power supplies and ground. The software driver defaults to a protective mode where conflicting faults are prevented to avoid accidentally shorting unintended paths, such as power to ground. A separate mode allows complete freedom in setting fault patterns.
-
product
Battery Ground Detector
BGD
Battery Ground Detectors supply contact closures for alarm indications at precise ground fault resistance settings.
-
product
PXI BRIC4 FIBO Matrix Dual 93x4 2pin brkout
40-592A-013
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
Phase Rotation Indicator DX2
STB Electrical Test Equipment, Inc
From the company who builds the popular analog ground fault detector comes the newest phase rotation indicator on the market. No other manufacturer offers a phase rotation indicator like STB's DX2 that will read up to 5kV! The phase rotation indicator is used to determine the phase sequence of three-phase voltages. This meter is most commonly used for phasing-in a power line which has supplied power to motors and plants. It is essential for testing departments of public utility systems for laboratory and field testing. The convenient and durable carrying case allows user to safely transport the unit to wherever the job takes them.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
DC Ground Fault Finder
FST-JD200
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1.
-
product
NI CAN No Termination Cable w/Power Terminals, HS/FD/LS, 1m
782578-01
9-Pin Female D-SUB With 2-Pin Female Power Screw Terminal to 9-Pin Female D-SUB CAN Cable - The DB9F-PT2F-DB9F CAN Cable, sometimes referred to as CAN Cable (with power terminals), connects C Series CAN Interface Modules, C Series LIN Interface Modules, or C Series Multiprotoco Interface Modules that have ports requiring external power with external CAN signals. The screw terminals on the cable allow for the direct wiring of power and ground to the port on the CAN interface. This cable is compatible with high-speed, flexible data-rate, and low-speed/fault tolerant CAN signals and is available with or without termination.
-
product
PXI BRIC4 FIBO Matrix Dual 155x4 2pin brkout
40-592A-115
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
Bus Bar Protection
BUS1000/2000
The BUS 1000/2000 is a solid state, high speed protectionsystem for the detection of phase-to-phase andphase-to-ground faults on bus bar installations. It can beused to protect high voltage bus bar installations of anyvoltage.
-
product
PXI BRIC4 FIBO Matrix Dual 20x4 3pin brkout
40-592A-001
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
Electric Shock Protection Analysis
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
product
Variable Power Supply
VS3
The VS-3 power supply is a very convenient portable, non-isolated “variable source” from 0 volts to 150 Vac or 0 volts to 150 Vdc and rated for up to 3 amps, thus the name VS-3. It is comprised of an illuminated voltmeter that reads to the first significant digit, AC variable system output voltage, DC variable system output voltage, logic output voltage and one sense (continuity) contact monitoring points. Banana jacks for connection of test leads are spaced at intervals that allow the use of dual banana test plugs if desired. The VS-3 is protected by two levels of overcurrent protection; AC input, and ground fault protection by a GFCI. All circuitry is housed inside a custom designed case made from 16 gauge steel. An Internal fan dissipates heat buildup and exhaust through louvered side vents built into the case. The carrying handle is designed with a “spring return to rest” position and is padded for comfort. The case has been sized for optimum portability and is balanced from the handle during transportation. The case has a powder coated finish that is scratch, chemical and weather resistant. Rubber padded feet support the case when in the upright position and a convenience receptacle is located on the side of the case. A unique feature of the VS-3 is that it contains “Magnet Packs” on the back of the case. These “Magnet Packs” can support the VS-3 and allow it to “hang” from any magnetic metal surface. The VS-3 can be powered by our UPS system, eliminating the need for an extension cord. The ability to magnetically attach the VS-3 near the source of connection and eliminating the need for an extension cord makes the VS-3 a “must have tool” for technicians.
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
NI CAN Single Termination Cable w/Power Terminals, HS/FD, 2m
782579-02
9-Pin Female D-SUB With 2-Pin Female Power Screw Terminal to 9-Pin Female D-SUB CAN Cable - The DB9F-PT2F-DB9F CAN Cable, sometimes referred to as CAN Cable (with power terminals), connects C Series CAN Interface Modules, C Series LIN Interface Modules, or C Series Multiprotocol Interface Modules that have ports requiring external power with external CAN signals. The screw terminals on the cable allow for the direct wiring of power and ground to the port on the CAN interface. This cable is compatible with high-speed, flexible data-rate, and low-speed/fault tolerant CAN signals and is available with or without termination.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
Surge Voltage Generator
SSG 2100
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 2100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
product
Under Ground Cable Fault Locator
Widely used in electrical and power generation sector for testing underground cables in order to detect any fault.
-
product
Voltman True RMS Industrial Safety Voltmeter
125
If you need a continuity function or harmonics are a problem then the Voltman TRMS is for you. Non sinusoidal waveforms from variable speed motors cause problems for most meters but the Voltman TRMS meter is specifically designed to produce accurate and dependable readings of distorted waveforms. When there is no voltage present the unit automatically tests for continuity, ground faults or shorts.
-
product
Mobile Cable Fault Location System
BAUR Syscompact 4000
BAUR Prüf- und Messtechnik GmbH
Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle
-
product
Surge Voltage Generator
SSG 1100
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
product
E-Z Check® Plus GFCI Circuit Tester
61-051
*Tests for correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and ground reversed with open hot in 3 wire, 120 VAC circuits*Simulates ground fault for testing GFCI*No-slip ergonomic design maximizes comfort*Premium neon lamps prevent false readings*Tough, impact-resistant case*2-year warranty
-
product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
product
Universal Locator
UL 30
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR UL 30. The UL 30 receiver is used together with a ground microphone (BM 30) and a surge voltage generator (SSG, STG) to pinpoint cable faults. With the coil integrated in the BM 30 for runtime measurement, the device determines the time difference between the magnetic and acoustic signal. This particularly offers special advantages when d ealing with faults difficult to locate acoustically.* Built-in speaker* Splashproof design* Large, illuminated display* Lightweight
-
product
Automatic Oil Insulation Test Kit
The test kit is fully automatic and has the facility forAuto/Manual selections. The operator simply needs thesample in the test vessel & selects the required test. Testingcan be done as per many international ( IEC & Europeanstandards ) which are programmed into the instrumentmemory . Stand time, Stir times & Rate of rise of appliedvoltage can be selected in Custom Mode also , one setof such selected mode can also be stored in the memory. In addition to the above set can also perform withstand test(proof) tests. In this test the set allows the set voltage to pre-set value & hold for one minute to see if breakdown occurs. The backlit LCD is used for user friendly operationsduring the test process. It also display fault condition messages such as open ground and cover open . All the user selected programmes are chosen through(4x3) key pad.The test results can be printed along with with test type, date, time, breakdown test voltage, averages and deviations. Voltage value can be measured & printed with a resolution of 0.1kV. In reprint option it is possible to have number of printouts for the last test. For each test the readings are recorded and stored in memory.
-
product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.