Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Wide Current Range Multiplexer Module, Quad 3-Channel, 2-Pole
42-514-103
The 40-514-103 (PXI) and 42-514-103 (PXIe) are low density multiplexers in quad 3-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
Digital Insulation Tester
200M
Laxtronics Instruments & Controls Pvt. Ltd
Digital insulation tester Model No: DIT200M is designed to carry out electrical insulation measurement in delicate or sensitive electronic sensors, transducers, modules and assemblies with test voltage from 1 to 30 Volts DC, its short circuit current is less than 100uA. The instrument can measure Resistance from 1 Meg Ohm to 1000 Meg Ohms.
-
product
Power Measurements Conditioner
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
product
Pressure To Current Measurement Trainer
Unitech Scales And Measurements Pvt. Ltd
Pressure to Current (P to I ) Trainer:This setup comprises of pressure chamber fitted on a base board. A pressure transducer and bourdon pressure gauge are fitted to the chamber. Digital pressure indicator with transmitter output is provided to display the pressure sensor by the pressure transducer. Transmitter output 4 to 20mA can be measured by a current meter. Foot air pump is provided to build the pressure.
-
product
Velocimeter
BC 114
*Piezoelectric converter of signal proportinal to the vibration speed RMS;*Standard current output signal 4…20 mA;*Used within vibration diagnostics systems as a vibration speed transducer;*Explosion-proof version.
-
product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
RM-26999, 4-Channel Power Measurements Conditioner
786328-01
The RM-26999 is a rack-mounted, signal conditioning device that connects to several simultaneous-sampling multifunction I/O devices for power measurements. It features four voltage input channels with peak voltages up to 2,000 V and four … current transducer ports for current measurements. The current transducer ports are optimized for flux-gate transducers by providing all the power, communication, and signal lines required for accurate measurements.
-
product
Flexible Current Sensor Probe
CTA
The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.
-
product
ADC DAC Module
ZET 220
ZET 220 ADC DAC module with 24-digit ADC converters is used for high-precision signals measurements in wide dynamic range. The signals to be measured are received from primary transducers – for instance, from sensors with 4-20 mA current output.
-
product
Multifunction Calibrator 15 ppm Basic Accuracy
MC142
Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.
-
product
Hall Effect DC Current Sensor
CYHCT-L20K
ChenYang Technologies GmbH & Co. KG
The sensor CYHCT-L20K is based on open loop principle and designed with a high galvanic isolationbetween primary conductor and secondary circuit. It can be used for measurement of DC current, DCpulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
DC Power Analyzer, Modular, 600 W, 4 Slots
N6705C
The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software
-
product
High Speed Data Acquisition
Data acquisition (DAQ) is the measurement, recording, analyzing, and presentation of real world phenomena. It includes electrical measurements such as voltage, current, power as well as measurements through sensors and transducers including temperature, pressure, flow, level, strain, acceleration, vibration, humidity, and more.
-
product
Rogowski AC Current Probe, 23 MHz, 3000 A
N7040A
The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.
-
product
Power modules
G.R.A.S. Sound & Vibration A/S
It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation
-
product
One Phase Electric Power/Energy Calibrator
MC133
The MC133 master unit model is a one phase electric power/energy calibrator. It can supply the device under test with single phase precise voltage and current with calibrated phase shift along with DC voltage and current capability. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. Simulated electric power can be set independently for each phase. Frequency can be set from 15Hz to 1 kHz with resolution 0.001Hz to 0.01Hz. The MC133 Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20mA or 10V for direct calibration of various types of power transducers and wattmeters.
-
product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
Split Core Hall Effect DC Current Sensor
CYHCT-C2TV
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used for measurement of DCcurrent etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
Calometric Power Meter
M1-25M/XXE
The M1-25M/XXE series instruments are high precision broadband Calorimetric Sensors operating in millimeter and sub-millimeter wave range on a principle of substitution of microwave power by direct current power, using an autocompensating transistor transducer. Calorimetric Sensor is supplied with Calorimetric Power Meter M1-25M (measurement and indicator block), which provides PC connection via USB interface.Calorimetric Power Meter with Calorimetric Sensor provides accurate absolute power measurements in single mode and multimode waveguides (Metal Dielectric Waveguide) which could be a priority for terahertz physics and technology.
-
product
Industrial Current Sensors
RCT
Power Electronic Measurments Ltd
The RCT range of AC current transducers are designed for permanent or semi-permanent installation and are available with industry standard outputs.
-
product
Accessories
Check out the full line of quality Amprobe accessories, which are field tested to help you get the most out of your Amprobe tools, including:*Rugged test leads of all types and sizes for Amprobe instruments*Current transducers for maximum accuracy and safety*Temperature accessories for surface, air/gas, or liquid temperature measurements*AC relays for low-voltage control circuits*Adapters, software, carrying cases and more
-
product
Plug-in Test Systems
FAME is the innovative, modular plug-in test system for measuring and testing tasks in protection technology for medium-voltage and high-voltage switchgear. The plug-in test system combines complex switching operations for testing the function of current transformers and voltage transducers, as well as tripping and signal contacts.
-
product
Load Cell Power Supply
MODEL PSMR
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
product
Power Analyzers
Real drive and test bench applicationMultiple power analyzer in one instrumentUltra flexible channel configurationWide range of fundamental frequencyCAN interface for automotive and test bench linkInternal current transducer supply and TEDS support
-
product
Rogowski AC Current Probe,30 MHz, 600 A
N7041A
The Keysight N7041A Rogowski coil current probe measures AC currents up to 600 A, with bandwidth ranging from 12 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
product
Primary Current Injection Test Set
T 3000
T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers
-
product
Complete Field Meter Site Testing Solution
7 Series
We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.
-
product
Power Line Transducers
Current Transducers measure AC Current and converts it to an industry standard output signal which is directly proportional to the measured input. These Transducers provide an output which is load independent and isolated from the input. The output can be connected to Controllers, Data-Loggers, PLC''''s, Analog / Digital Indicators, Recorders for display, analysis or control. They are ideal for SCADA, Energy Management, Telemetering for Remote, Local as well as Central Monitoring Systems.
-
product
Automatic Relay Test Set
DRTS 33
DRTS 33 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 3 Current and 3 Voltage generators simultaneously available.
-
product
Process Voltage & Current Data Loggers
Monitor and log virtually any process voltage or current output from your transducers.
-
product
Servo type Accelerometer
A motion is sensed by a displacement detector, a current is fed to the coil to get back the pendulum mass to the original position. This current will be proportional to the acceleration, that is converted to an output voltage. The Servo type accelerometer is for the Earthquake Monitoring or measurements of micro tremor on the Civil Engineering Structures because of its higher sensitivity and stability or more accurate phase responses in the lower frequency range than those of other vibration transducers.