Filter Results By:
Products
Applications
Manufacturers
Multiplexers
Combine multiple signals into one signal.
See Also: Switching, Switching Matrix, High Voltage Switching, Switching Matrices, General Purpose Switch
- Pickering Interfaces Inc.
product
PXI 1 Bank of 80 Channel 2 Pole MUX
40-615-022-1/80/2
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
PXI/PXIe Microwave Multiplexer, Single SP8T, 18 GHz, 50 Ω, SMA, Terminated, Failsafe
40-788-021-T
The 40-788-021-T (PXI) and 42-788-021-T (PXIe) are single failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
product
PXI Very High Density Multiplexer, 49-Channel, 4-Pole
40-675A-002-49/4
The 40-675A-002-49/4 is a 49-channel, 4-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
product
PXI Multiplexer, Single 48-Channel, 1-Pole
40-632A-021-48/1
The 40-632A-021-48/1 is a single 48-channel, 1-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
product
LXI Microwave Multiplexer, SP6T, 8-Bank, 26.5GHz, 50Ω, SMA
60-800-308
Our 60-800-308 is a 8 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Dual 2x2 Optical MUX LC Multi-Mode
60-851-405
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber, LC Connectors
42-850A-414-M62.5
The 40/42-850A-414-M62.5 is a PXI/PXIe 4-channel multiplexer with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
PCI 2 Amp Multiplexer, Single 8-Channel, 8-Pole
50-635A-004
The 50-635A-004 is a single 8-channel, 8-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI/PXIe Microwave Multiplexer, Single SP4T, 50 GHz, 50 Ω, SMA-2.4, Terminated, Failsafe
42-785C-451-T
The 40-785C-451-T (PXI) and 42-785C-451-T (PXIe) are single failsafe SP4T 50 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI/PXIe High Voltage Multiplexer, Dual 11-Channel, 2-Pole
42-321-125-HI
The 40-321-125-HI (PXI) and 42-321-125-HI (PXIe) are dual 11-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
PXI Dual SP6T Multiplexer 18GHz 50, SMA, Terminated
40-785B-522-T
The 40-785B-522-T is a dual 6-channel 18GHz terminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI 2A Multiplexer, 2-Bank, 4-Channel, 16-Pole
40-614B-014
This 2-bank, 4-channel, 16-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PCI 2 Amp Multiplexer, Single 64-Channel, 1-Pole
50-635A-001
The 50-635A-001 is a single 64-channel, 1-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
LXI Microwave Multiplexer, 50Ω 6-Channel 4-Bank 18GHz SMA
60-801-204
The 60-801-204 is a 6-channel, 4-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode, 9/125 Fiber
40-852A-318-HI
The 40/42-852A-318-HI is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 14-Bank 26.5GHz SMA
60-802-314
The 60-802-314 is a 4-channel, 14-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
PXI Triple SP6T Multiplexer 26.5GHz 50 SMA
40-784A-033
Pickering Interfaces’ range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50Ω and are capable of switching signals up to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors
-
product
PXI-2596, 26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module
778572-96
26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2596 is an RF signal multiplexer switch with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use the PXI‑2596 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
PXI 5 Banks of 16 Channel 1 Pole MUX
40-615-021-5/16/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
PXI 4 Banks Of 20 Chan Screened 1 Pole MUX
40-615-021-S-4/20/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
product
PXI High Density Multiplexer, 1-Bank, 80-Channel, 1-Pole
40-615A-018
The 40-615A-018 is a 1-bank, 80-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
product
PXI RF Multiplexer, 10x SP4T, 1.3 GHz 75 Ω, SMB Connectors
40-755-310
The 40-755-310 is a 10xSP4T 75 Ω multiplexer and is part of a range of high density RF multiplexers available in 50 Ω and 75 Ω variants with up to 10xSP4T switches in a single PXI module. They are available with two connector options; SMB that provides a frequency range of 1.8 GHz (50 Ω) / 1.3 GHz (75 Ω), or multiway which limits the bandwidth to 1.3 GHz but offers a high density solution occupying one PXI slot.
-
product
PXI 3A Power MUX BRIC, 32-Channel, 6-Pole
40-571-404
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 67GHz, 50Ω, SMA-1.85
40-785C-572
The 40-785C-572 (PXI) and 42-785C-572 (PXIe) are dual SP6T 67GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI/PXIe RF Multiplexer, Single 4-Channel, 3GHz, 75Ω, MCX
40-832A-101
The 40-832A-101 (PXI) and 42-832A-101 are 75 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXI/PXIe Microwave Multiplexer, Single SP4T, 50 GHz, 50 Ω, SMA-2.4, Remote Mount, Failsafe
42-785C-451-E
The 40-785C-451-E (PXI) and 42-785C-451-E (PXIe) are single failsafe SP4T 50 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI-2796, 40 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module
782356-01
40 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2796 offers a high-density, unterminated multiplexer with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.
-
product
PXI 10A Power Multiplexer, 2-Bank, 16-Channel
40-661A-003
The 40-661A-003 is a single pole, 2-bank, 16-channel PXI power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 18GHz, 50Ω, SMA, Remote Mount
40-784B-022-E
The 40-784B-022-E (PXI) and 42-784B-022-E (PXIe) are dual SP6T 18GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-433-TE
The 40-785C-433-TE (PXI) and 42-785C-433-TE (PXIe) are triple failsafe SP4T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI/PXIe High Voltage Multiplexer, Dual 23-Channel, 2-Pole
40-321-128-HI
The 40-321-128-HI (PXI) and 42-321-128-HI (PXIe) are dual 23-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.