Filter Results By:
Products
Applications
Manufacturers
-
product
16-Channel VME RTD/Resistance Input Module
V410
The V410 is a 6U VME module that provides sixteen independent analog inputs that may be used to read RTDs, thermistors, and other similar resistive sensors. It can also read cryogenic diodes. Users may set input range and adjust other settings at VMEbus speed, and depending on the range selected the microprocessor will do the necessary calculations and output voltage, resistance, or temperature. Temperature conversion is available for 100Ω and 1000Ω, series 385 and 392, platinum RTDs.
-
product
Cryogenic Temperature Sensors
Platinum
PT-100 platinum resistance thermometers (PRTs) serve an important role in both cryogenic research and industrial cryogenics applications.
-
product
Reference Thermometers
Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
product
High and Low Temperature Humidity Chamber
GDJS/GDJW
•The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip. •The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1℃ and humidity is 0.1%R.H •The temperature sensor is platinum PT100 Ohms/MV resistor •The heating system is full separately system which produced by Nickel chromium alloy electric heating type heater •The cold system is applied by fully enclosed fan cooled single-stage and cascade refrigeration mode, the compressor is from France TECUMSEH brand which can allow you get after sales support from many countries •The cyclical system is applied by High temperature low noise air conditioning type motor and Multi blade centrifugal wind wheel •The safety self-protection function include Electric leakage, short circuit, over temperature, motor overheating, compressor pressure, overload, over-current protection •Working Power: AC380V±10% 3phases and frequency 50Hz/60Hz •Working Environmental: Temperature is 5℃~+30℃ Humidity ≤85%R.H
-
product
Temperature Sensors
Screw in positive mount installationGrease zerk for bearing lubrication1/2” NPT conduit entry (steel body)NTC version - continuous temperaturePTC version - trip points from 122°F to 194°FPT100 version - platinum RTDClass 2 Div 1, Div 2 Approved
-
product
Independent 24-bit Sigma-Delta Type (One for Each Channel)
TR1
The TR1 provides 8 channels which can be individually programmed as a Thermocouple (TC) or a Resistance Temperature Detector (RTD) measurement interface. When configured as a TC, the channel can interface with virtually all thermocouple-type NIST temperature ranges. When configured as an RTD, the channel can interface to two, three and four-wire platinum RTD sensor configurations.
-
product
RJ45 Port Saver
#21025C
Extend the life of your tester by using the RJ45 PortSaver as your sacrificial cable. Eliminates the wear and tear from constantly plugging in and out of the tester port and minimizes the risk of damaging the RJ45 jack if the connector contacts are not crimped completely. Compatible with all Platinum Tool testers with built-in […]
-
product
Temperature Transmitter
Knick Elektronische Messgeräte GmbH & Co. KG.
Transmitters for platinum temperature sensors and thermocouples in 6 mm housing with calibrated range selection. Functional safety up to SIL 2, SIL 3 redundant to parameterization via interface or intuitively, directly on the device. Universal use with 24 V DC or AC power supply.
-
product
8 Channels, RTD Measurement
RT1
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
product
RTD Thermometers
Precision Platinum Temperature Sensor, High Accuracy With 0.01°C Resolution, Automatic Locked Push-pull Connector For Easy Connection, Large Back Light LCD
-
product
Larger Size Chambers
Platinum
The ESPEC Platinum series are top quality temperature/humidity chambers in larger sizes for temperature cycling of 2 to 15°C per minute. High performance, reliable Scroll compressors(most units). One adjustable shelf with heavy-duty support rails. Non-metallic thermal breaks at doorframe and cable ports to eliminate exterior frosting or hot spots
-
product
Probes/Sensors
Fluke Calibration provides high-quality secondary platinum resistance thermometers (PRTs); industrial PRTs; high-temperature, fast-response, and other special-application PRTs; thermistor standards; secondary thermistor probes; type R and type S thermocouples. These probes may be used for temperature measuring, temperature calibration, temperature monitoring and temperature validation.
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Conductivity Electrode
As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.
-
product
Diode Temperature Monitor
SIM922
Stanford Research Systems, Inc.
The SIM922 Diode Temperature Monitor and the SIM923 Platinum RTD Monitor are designed to measure four sensors simultaneously. Based on the modular SIM platform, they provide high-performance and multiple-channel capability in a small footprint.
-
product
Portable XRF Analyzer
GoldXpert
XRF is a widely used, proven, and accepted method of chemistry analysis and determination of purity and fineness of precious metals. XRF analysis is a multielemental testing alternative that is quicker and less expensive than fire assay and chemical tests. XRF provides on-the-spot analysis of your silver, platinum, and PGM metals and impurities, making it an easy way to boost customer confidence and ensure dealer reliability.
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
Grid Electrode
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
product
Micro Melting Point Instrument
DRK8026
Shandong Drick Instruments Co., Ltd.
Determine crystal melting point of the substance to make sure its purity. Mainly used for determining the meltingpoints of medicine,dyestuff,spice and other organic crystal compounds.Using photoelectric automatic detection, Dot matrix LCD display picture technology, digital keyboard input, and has the initial melting, final weld automatic display,automatic recording of melting curve, automatically determine the melting point of the mean value function. The temperature system uses highly linear platinum resistance as detection elements and PID regulation technology, improved the melting point’s precision and reliability. The instrument establishes communication with PC through the USB or RS232, printing or saving the curve and it uses capillary Pharmacopoeia as sample tube.
-
product
FTP Patch Cable, 5″ C6, 4/Clam
#610025C
Platinum Tools’ premium 5″ Cat6 FTP Patch Cables are made with testing networks in mind. Plug in and out all day long and know you will have consistent and precise connectivity every time. Designed for repititive, long cycle life! 849160007951
-
product
Tracking Index Test Apparatus
CX-L19
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
product
Dual MAX31865 PT-1000 RTD to Digital Breakout
SEN-30202-PT1K
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information.
-
product
RTD Sensors
Are sensors used to measure temperature. Many RTD elements consist of a length of fine wire wrapped around a ceramic or glass core but other constructions are also used. The RTD wire is a pure material, typically platinum, nickel, or copper.
-
product
Capillary-fill sensors
Zimmer and Peacock have launched the world's first capillary fill sensor for the Research and Development market, both academia and industry. We provide these capillary-fill sensors in gold, platinum and carbon.
-
product
Citadel CTD-ES
Teledyne Marine RD Instruments
The CITADEL CTD-ES incorporates proven inductively coupled conductivity sensor technology with a platinum resistance thermometer and micromachined silicon pressure sensor to provide highly accurate and stable readings.
-
product
High-Temperature and High-PressurepH Electrodes
UltraDeg
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
product
100 Ohm Platinum RTD Thermometer
869
Models 868 and 869 digital RTD thermometers measure temperatures from -360F to 1100F, (-220C to 630C). Compatible with either 3 or 4 wire RTDs, temperature measurement is performed with a best accuracy of .4F(.3C). These thermometers are specially constructed with a heavy duty ABS case specifically designed for industrial use.
-
product
Platinum RTD Sensor - PT100 - 3 Wire 1 meter long
For precision temperature sensing, nothing beats a Platinum RTD. Resistance temperature detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature changes, basically a kind of thermistor. In this sensor, the resistor is actually a small strip of Platinum with a resistance of 100 ohms at 0C, thus the name PT100. Compared to most NTC/PTC thermistors, the PT type of RTD is much most stable and precise (but also more expensive) PT100's have been used for many years to measure temperature in laboratory and industrial processes, and have developed a reputation for accuracy (better than thermocouples), repeatability, and stability.
-
product
Electrochemical (Molecular Electronic Transfer) Motion Sensor transducers
The Molecular Electronic Transfer Technology
The basic design of the MET transducer, shown in Figure 1. The transducer is contained in a channel, 1, of a sensor filled with a specially prepared electrolytic solution. It consists of four fine platinum mesh electrodes, two anodes, 2, and two cathodes, 3, separated by thin, microporous ceramic or polymer spacers 4. Such an assembly is held together by a housing 5. To measure the motion of the fluid, it must be converted into an electrical signal. One way of achieving this is by using the convective diffusion of the ions in the electrolyte. At the heart of a MET device are inert electrodes at which a reversible redox reaction occurs, which does not involve either plating of a metal or evolution of a gas.
-
product
Temperature Probe, 100 ohm, RTD, Air/Gas
8696
Model 8696, platinum RTD probe is designed for measuring air and other gaseous mediums. The sheath is 8" long and is constructed with #304 stainless steel. The probe tip is protected from temperature fluctuations by a perforated shield. The probe''s 4-inch handle is connected to a thermoplastic coil cord that extends from 1-1/2 feet to 5 feet.