Kingrun Instrument Co., Ltd.
Measuring device for transmitting and converting high voltage. The professional high technology company collects scientific research developing,producing and sales for an inegral whole.
- +86-312-5959618
- +86-312-5926968
- kingrun.steven@gmail.com
- Building2# Torch High-Tech Park
Baoding City, 071000
China
-
product
Extra-Ground Current Impuision Equipment
JYQ
Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.
-
product
Winding Resistance Tester
JYR20S/10S
DC winding resistance testing is regarded as another essential routine screening tool. It indicates problems such as loose, defective or incorrect connections, which cause enough transformer failures each year to be regarded as a failure category of its own.
-
product
Transformer Performance Tester
JYW6100
JYW6100 Transformer No-loads and On-loads tester power factor tester is suitable for loss testing of low power factory transformer such as amorphous alloy transformer, with high precision and data loc
-
product
Transformer Oil Tester
GTD-61A
1. The GTD-61A Automatic Oil Tan Delta(OTD) & Oil dielectric loss tester is highly automated, allowing for the measurement of temperature rise, dielectric loss, and resistance in one go.
-
product
Transformer Winding Resistance Tester
KRI 9310
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
product
Winding Resistance Tester
JYR-50C/40C/20C
1. With demagnetization function.2. Testing range reach to 20k3. Also apply to testing tranformer with high winding resistance.
-
product
Earthing Resistance Tester
JYD-10A
transformer neutral grounding resistor is the vital need in medium voltage AC distribution network that are also called by different names like Neutral Earthling Resistors. They are taken into use to limit the current that would flow through the neutral point of a transformer or generator in the event of an earth fault. They are also used for resistance grounding of connected generators and transformers.
-
product
Contact Resistance Tester
JYL
As a high current passes through a pair of mechanically independent metallic contacts, the contact resistance must be as low as possible. Increasing the contact resistance of the contact often causes a large voltage drop on the contact, which reduces the input power of the load equipment. If the contact resistance of one or two contacts becomes large, the three-phase voltage of the load equipment will be unbalanced, causing phase loss operation.
-
product
Contacts Resistance Tester
JYK II
•Instrument IPC architecture for domestic production of all models of metal contacts SF6 switchgear, GIS combination of electrical, vacuum switch, oil switch and column switches, contacts and so on.•Sensor: Acceleration speed sensor, rotation speed sensor, linear stroke sensorinstallation is very easy and simple.•Trigger: The trigger, external trigger, the sensor is triggered. Sensor can trigger the circuit breaker manually switching characteristic test, such as a manual column pole division switch.
-
product
Transformer Performance Tester
6691
applying ±90V voltage on the winding of the transformer demagnetized and get the voltage value on the terminal and the current value in the winding to draw the hysteresis characteristic curve. This method can be used for linear quantitative analysis of residual magnetism in transformers, and fast demagnetization can be achieved by tracking hysteresis curves. The analyzer can measure magnetism residual rate before and after demagnetization.
-
product
Portable Winding Resistance Tester
1. Handheld winding resistance meter2. Conversion function for standard temperature resistance.3. 500 test data can be saved and download by flash disk.4. Temperature testing function.
-
product
Substation Series Testers
GTPD-92
Partial discharge(PD) is a pulsed discharge that produces a series of physical phenomena and chemical changes such as light, sound, electrical and mechanical vibrations in and around electrical equipment.
-
product
Capacitance and Inductance Tester
JY6700
Capacitance measurementsInstrument can test take a single capacitor without stitches in test group capacitance to bring convenience to test. It will show test results of capacitance while show test
-
product
Contact Resistance Tester
JYL-200B/100B
Product description: JYL-200B/100B contact resistance tester can measure contact resistance of high voltage switches and circuit breakeres, also can test primar side resistance of transformer and grounding wire in groups
-
product
Transformer Heat Run Tester
1. Suitable for all transformers below 240MVA heat run test and winding resistance testing.2. Printing heat run data automatically.3. With double power supply, can test high voltage side and low voltage side simultaneously and test any operation respectively.4. With anti breakage protection function of inductive test items.