Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States
-
product
Process Ozone Monitor
Model 454
Teledyne Advanced Pollution Instrumentation
The Model 454 is a microprocessor based gas monitor for measuring mid to high concentrations of ozone in oxygen or air.Available in a standard DIN panel mount configuration with a 4-digit LED display, the compact design provides ease of mounting and installation.
-
product
Chemiluminescence NH3 Analyzer
Model T201
Teledyne Advanced Pollution Instrumentation
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter (see "Features" tab for external converter photo) to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.
-
product
Portable Trace-Level O3 Calibrator
Model T753U
Teledyne Advanced Pollution Instrumentation
The Model T753U is a portable, microprocessor based precision Calibrator for Ozone gas instruments and sensors. Using a sophisticated Ozone generation system, combined with a sensitive photometer and pneumatic design, the T753U produces stable and reliable concentrations of Ozone in a convenient and rugged package based on our popular T750U Portable Multigas Calibrator platform. The T753U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field for virtually any application. An internal zero air option extends the T753U's capabilities to also provide a clean and dry source of zero air, eliminating the need for a separate source of zero air. The internal zero air source module contains a software driven electronic inlet valve manifold allowing the calibrator to automatically switch between internal and external zero air sources depending on the application needs.
-
product
High Range UV Fluorescence SO2 Analyzer
Model N100H
Teledyne Advanced Pollution Instrumentation
The Model N100H instrument uses the proven UV fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high range SO2 gas. The instrument includes interferent rejection, providing a simple and precise solution for a broad range of continuous emission monitoring systems (CEMS) and stack testing applications.
-
product
Process Ozone Monitor
Model 465M
Teledyne Advanced Pollution Instrumentation
The Model 465M is a microprocessor based medium range ozone monitor for measuring process ozone concentrations in water treatment, food processing, and research applications. The design has been specifically optimized for applications requiring the measurement of ozone at near-ambient pressure such as water treatment contactor off-gas measurement. The Model 465M has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465M is available in a NEMA 4X wall mount enclosure.
-
product
Ozonator Controller
SCI-552
Teledyne Advanced Pollution Instrumentation
The SCI-552 is a system controller for ozone delivery systems that provides electronic control interfaces for a number of typical system components, including: ozone generators, EV valves, mass flow controllers, back-pressure controllers, Teledyne API 452 ozone sensors, Teledyne API 470 dissolved ozone sensors, and a water chiller.
-
product
UV Fluorescence TRS Analyzer
Model T102
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
product
Dissolved Ozone Analyzer
Model 470
Teledyne Advanced Pollution Instrumentation
The Model 470 is a state-of-the-art Dissolved Ozone Sensor designed for semiconductor Wet Bench tools and many other industrial processes. It provides continuous measurement of dissolved ozone in deionized water or sulfuric baths with concentrations up to 150 mg/L. The Model 470 is “clean-ready” for high purity semiconductor processes, and is designed to be simply spliced in-line in the recirculation loop of any wet bench tool with flow rates up to 150 SLPM.
-
product
Process Ozone Monitor
Model 465H
Teledyne Advanced Pollution Instrumentation
The Model 465H is a microprocessor based high concentration ozone monitor for measuring ozone in process gas streams in water treatment, food processing, and research applications. The 465H has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465H is available in a NEMA 4X wall mount enclosure.
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
High Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200H
Teledyne Advanced Pollution Instrumentation
The Model N200H uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
product
Paramagnetic O2 Analyzer Optional CO2 Sensor
Model T802
Teledyne Advanced Pollution Instrumentation
The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.
-
product
CAPS True NO2-NOX-NO Analyzer
Model N500
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
product
UV Absorption O3 Analyzer
Model T400
Teledyne Advanced Pollution Instrumentation
The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.
-
product
Gas Calibrators and Zero Air Generators
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.